NAPCO NP-AMOD8 Instructions Manual
1DESCRIPTIONThe NP-AMOD8 is an access power controller that dis-tributes one (1) 12-24 volt AC or DC input over eight(8) independently controlled (and fuse protected) out-puts. In addition, these 8 outputs can be configured asdry form "C" contacts. The outputs are activated by anopen collector sink or normally open (NO) dry triggerinput from a Card Reader, Access Control System,Push Button, Keypad, PIR, etc. It will direct power tomany access control hardware devices including Elec-tric Strikes, Magnetic Locks and Door Holders, etc.Outputs operate in both fail-secure and fail-safemodes. The NP-AMOD8 can be powered by one com-mon power source that provides power for both thelocking devices and board operation, or two totally in-dependent power sources, one supplying power forlock / accessory power and the other for board opera-tion. The FACP Interface enables Alarm Monitoring,Emergency Egress, HVAC Shutdown, Elevator Recallor can be used to trigger other auxiliary devices. Thefire alarm disconnect can be configured for the follow-ing modes: Eight (8) outputs unaffected (Fail Safe) orEight (8) outputs affected (Fail Secure). Each output isindependent controlled.FEATURES• 12 to 24volt AC or DC Operation (setting not required).(.5amp @ 12volt, .22amp @ 24volt current consumptionwith all relays energized).• Power supply input options:a) One (1) common power input (board and lock power).b) Two (2) isolated power inputs (one (1) for boardpower and one (1) for lock power).• Eight (8) Access Control System trigger inputs.Input options:a) Eight (8) normally open (NO) inputs.b) Eight (8) open collector sink inputs.c) Any combination of the above.• Eight (8) independently controlled outputs.Output options:a) Eight (8) fail-Safe and/or fail-Secure power outputs.b) Eight (8) dry form "C" 5 amp rated relay outputs.c) Any combination of the above.• Eight (8) auxiliary power outputs (unswitched).• Output fuses are rated 3. amp.• Main fuse is rated at 10 amp. Note: Total output currentis determined by the power supply, not to exceed a maxi-mum of 10 amp total.• Red LEDs indicate outputs are triggered (relays ener-gized).• Fire Alarm disconnect (latching or non-latching).Fire Alarm disconnect input options:a) Normally open (NO) or normally closed (NC) dry con-tact input.b) Polarity reversal from FACP signal circuit.Fire Alarm disconnect output options:a) Eight (8) outputs affected.b) Eight (8) outputs unaffected .• FACP output relay (form "C" contact rated @ 1 amp28VDC not evaluated by UL).• Green LED indicates when FACP disconnect is triggered.• Removable terminal blocks facilitate ease of installation.Board Dimensions: 203.2mm L x 114.3mm W x 45mm HINSTALLATION INSTRUCTIONS1. Mount NP-AMOD8 in desired location/enclosure.Note: Keep power limited wiring separate from non-power limited wiring (115VAC / 60Hz Input, Batterywires). Minimum .25" spacing must be provided.Carefully review:• Terminal Identification Table• Typical Application Diagram• LED Diagnostics• Hook-up Diagrams2. Power supply input:The NP-AMOD8 can be powered with one (1) powersupply which will provide power for both board op-eration and the locking devices or two (2) separatepower supplies, one (1) to provide power for theboard operation and the other to provide power forthe locking devices.Note: The input power can be either 12 to 24 voltsAC or DC (.5amp @ 12volt, .22amp @ 24volt currentconsumption with all relays energized).(a) Single power supply input:If the NP-AMOD8 and the locking devices are to bepowered using a single power supply, connect theoutput (12 to 24 volts AC or DC) to the terminalsmarked [- Control+].(b) Multiple power supply inputs :When the use of two power supplies is desired,jumpers J1 and J2 (located to the left of the power/R333 Bayview AvenueAmityville, New York 11701For Sales and Repairs, (800) 645-9445For Technical Service, (800) 645-9440NP-AMOD8ACCESS POWER CONTROLLERWI1329A 12/05© NAPCO 2005 |
Related manuals for NAPCO NP-AMOD8
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine