Model 125X MiniPrinter Series User’s Manual4Interface-SerialCharacter BufferingPrint MethodCharacter MatrixCharacter SpacingLine Feed SpacingPrint SpeedPaperPowerAC VoltageDC VoltageExternal DimensionsInterface-ParallelSpecificationsAvailable baud rates: 300, 600, 1200, 2400, 4800,9600, 19200Voltage levels:RS-232C: -9 Volts to +9 VoltsTTL: 0 Volts to +5 Volts20mA current loopRS-2485: 200mV differentialCharacter format:Standard ASCII character set—10 or 11 bits percharacter, 7 or 8 data bits.Even or odd parity selection for 7 data bits.Bit mapped graphics—10 bits per characterBusy signal - Clear to Send (CTS, XON-XOFF)36-pin Centronics connector1.5K standard8K optionalApproximately 9,500 byte capacity with optioninstalled.Impact dot matrix5 x 5, 5 x 7, 5 x 824 column: 12.8 characters/inch32 column: 17 characters/inch40 column: 21 characters/inch7.4 lines per inch130 lines per minute for 24 column110 lines per minute for 32 and 40 columnTable top: 2.25”W x 2.75”D; 0.44” I.D.Panel mount: 2.25”W x 1.25”D1.5 Watts (idle), 15 Watts maximum while printing9 VAC (120 VAC stepdown converter included)Multi-national converters optionalOptional 9-12 VDC140mA idle, 1 amp with 100% printing, 5.5 amp peakwith 100% printing4.6”W x 5.0”L x 2.2”H