System Board, Connectors, and Error Messages D-7Message Entering SETUP…Cause Starting the Setup Utility program.Message Extended memory not working or notconfigured properly at offset:nnnn.Cause Extended RAM failed at offset:nnnn.Message Fixed Disk 0 or Fixed Disk 1 Failure, or FixedDisk Controller Failure.Cause Fixed (hard) disk drive is not working or notconfigured properly.Solution Make sure the drive is correctly identified in theSetup utility program and is properly attached.Message Failing Bits:nnnn.Cause The hex numbernnnn is a map of the bits atthe RAM address that failed the memory test.Each 1 (one) in the memory map indicates afailed bit. The failed memory could be inSystem, Extended or Shadowed memory.Message Incorrect Drive A Type or Incorrect Drive BType – run SETUP.Cause Type of floppy drive A or B is not correctlyidentified in Setup Utility program.Message Invalid NVRAM media type.Cause Problem with NVRAM (CMOS) access.Message Keyboard Controller error.Cause The keyboard controller failed its test. Thekeyboard may need to be replaced.