5 - 2 Hardware Specifications______________________________________________________________________________________________________________________________________________________________________Document Revision 4 Electra Elite IPKSECTION 3 C ABLING R EQUIREMENTS AND SPECIFICATIONSThis section provides cabling requirements and specifications for various equipmentused in the Electra Elite IPK system.The KSU is connected with each of the Multiline Terminals and Single LineTelephones by a separate twisted 1-pair cable or 2-pair cable (only for MultilineTerminals). (Refer to Table 5-1 D term Series i or Dterm IP Terminal Loop Resistanceand Cable Length and Table 5-2 Electra Elite/D term Series E Multiline Terminal LoopResistance and Cable Length for the loop resistance and cabling requirements forMultiline Terminals and adapters.)Table 5-1 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable LengthTerminal orAdapterMaximumLoopResistance(without ACAdapter)(Ohms)By Twisted1-Pair Cable(without ACAdapter)24 AWGBy Twisted2-Pair Cable(without ACAdapter)24 AWGMaximumLoopResistance(with ACAdapter)(Ohms)By Twisted1-Pair Cable(with ACAdapter)24 AWGBy Twisted2-Pair Cable(with ACAdapter)24 AWGDTH-8-1 TELDTR-8-1 TEL 37 700 1400 107 2000 2000DTH-8D-1 TELDTR-8D-1 TELITH-8D-2/3 TEL37 700 1400 107 2000 2000DTH-16-1 TELDTR-16-1 TEL 35 660 1320 107 2000 2000DTH-16D-1 TELDTR-16D-1 TELITH-16D-2/3 TEL35 660 1320 107 2000 2000DTH-32D-1 TELDTR-32D-1 TEL 26 500 1000 107 2000 2000DTH-16LD-1 TEL 37 700 1400 107 2000 2000DCR-60-1 Console — — — 107 2000 2000 An AC Adapter is required.