3210. TOOLS10-1. PEN SETTINGSEither when using the stylus pen for the first time or changing the installation place of the projector, make sure toperform calibration for letting the projector to recognize the stylus pen position properly.There are four options for the pen set up.AUTO CALIBRATION Adjust the stylus pen position automatically. Select this for easy adjustment.MANUAL CALIBRATION Adjust the stylus pen position manually. Select this for precise position adjustment asfor permanent projector installation.REMOTE PEN Operation by a computer mouse can be performed by the stylus pen touch.For utilizing the remote pen, connect the USB-B port on the projector and the USB-Aport on the computer by the supplied USB cable.NOTE:• Before starting to use the remote pen, install the latest IWB Setup Software for the white boardkit onto the computer and perform calibration. The latest IWB Setup Software for the whiteboard kit is available to download from our web site:http://www.nec-display.com/dl/en/pj_soft/lineup.htmlTOUCH MODULE, ADJUST-MENTFor using the separately sold TOUCH MODULE. Display the TOUCH MODULE adjust-ment screen.After performing calibration of the stylus pen, you can use the stylus pen on the WHITEBOARD, etc. in the APPSMENU.NOTE:• Do not use the stylus pen with wet hands and use it in water splash apprehended place.• If a part of human body gets close or contacts with the screen, it may cause of malfunction. Make sure to keep certain distancefrom the screen surface.• It will cause of malfunction if you put hands onto the screen.• For drawing precise letters and drawings onto the separately sold Touch Module, please use the stylus pen.• If the calibration is performed when the onscreen menu is displayed on, it may cause of malfunction. Confirm if the onscreenmenu is disappeared before performing the calibration.Automatic Calibration1. Focus on the [AUTO CALIBRATION] and then press ENTER button.Start calibration.Position adjustment will be completed within 5 to 8 seconds and the message of the calibration completion will bedisplayed on.Manual Calibration1. Focus on the [MANUAL CALIBRATION] in the [PEN SETTINGS] and press ENTER.The projection screen will switch to the manual calibration screen and a red dot will be indicated at the left top ofthe screen.2. Touch the center of dot by the stylus pen.After touching the red dot, it moves to 25 positions in order.PRESS BRIEFLY ON THE RED DOT WITH STYLUS (NO FINGER) TO CALIBRATE (SET TOP LEFT).PRESS [EXIT] TO CANCEL CALIBRATION