E-4204. VOLUME Gain DataFunctionThe external control equipment changes the VOLUME gain data of the plasmamonitor.Transmission DataDFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKSDATA00: USER SOUND Gain Flag 05HDATA01: VOLUME Gain Flag 01HDATA02: VOLUME Gain 00H: Step 00AH: Step 10 (Default)2AH: Step 42ACK7FH 60H 80H 7FH 02H DATA00 DATA01 CKSDATA00: USER SOUND Gain Flag 05HDATA01: VOLUME Gain Flag 01H05. AUDIO Mute OnFunctionThe external control equipment switches on AUDIO Mute of the plasma monitor.Transmission Data9FH 80H 60H 3EH 00H CKSACK3FH 60H 80H 3EH 00H CKS06. AUDIO Mute OffFunctionThe external control equipment switches off AUDIO Mute of the plasma monitor.Transmission Data9FH 80H 60H 3FH 00H CKSACK3FH 60H 80H 3FH 00H CKS07. CONTRAST Gain DataFunctionThe external control equipment changes the CONTRAST gain data of the plasmamonitor.Transmission DataDFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: CONTRAST Gain Flag 07HDATA02: CONTRAST Gain CCH : -52FFH: -0100H: 001H: +0114H: +20ACK7FH 60H 80H 7FH 02H DATA00 DATA01 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: CONTRAST Gain Flag 07H08. BRIGHT Gain DataFunctionThe external control equipment changes the BRIGHT gain data of the plasmamonitor.Transmission DataDFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: BRIGHT Gain Flag 08HDATA02: BRIGHT Gain E0H: -32FFH: -0100H: 001H: +0120H: +32ACK7FH 60H 80H 7FH 02H DATA00 DATA01 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: BRIGHT Gain Flag 08H09. SHARPNESS Gain DataFunctionThe external control equipment changes the SHARPNESS gain data of theplasma monitor.Transmission DataDFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: SHARPNESS Gain Flag 06HDATA02: SHARPNESS Gain F0H: -16FFH: -0100H: 001H: +0110H:+16Only when a RGB signal is connectedDATA02: SHARPNESS Gain 01H: 102H: 203H: 304H: 4ACK7FH 60H 80H 7FH 02H DATA00 DATA01 CKSDATA00: USER PICTURE Gain Flag 01HDATA01: SHARPNESS Gain Flag 06H