NEC Solutions (America), Inc.Visual Systems84VP5/84VM5 Installation Guide (using four 42VM5 or 42VP5 Plasma Displays)(also a reference for optional Quad Mount used with 42VM5 or 42VP5) v1.3www.necvisualsystems.com Page 12 of 140DH : Bottom left selected (9 screens)0EH : Bottom middle selected (9 screens)0FH : Bottom right selected (9 screens)DATA02 (DISP MODE)00H : SPLIT01H : BLANKING11.MULTI MODE RequestFunctionExternal control apparatus can know the MULTI MODE information on a plasma monitor.Transmission Data1FH 80H 60H 3BH 00H CKSACK7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKSDATA00 (SCREEN DIVIDER SETTING)01H : Single mode02H : Multi mode 1 screens03H : Multi mode 4 screens04H : Multi mode 9 screensDATA01 (POSITION OF DIVIDE)01H : Upper left selected (4 screens)02H : Upper right selected (4 screens)03H : Lower right selected (4 screens)04H : Lower left selected (4 screens)07H : Top left selected (9 screens)08H : Top middle selected (9 screens)09H : Top right selected (9 screens)0AH : Middle left selected (9 screens)0BH : Middle center selected (9 screens)0CH : Middle right selected (9 screens)0DH : Bottom left selected (9 screens)0EH : Bottom middle selected (9 screens)0FH : Bottom right selected (9 screens)DATA02 (DISP MODE)00H : SPLIT01H : BRANKING12.AUTO ID SET STARTFunctionExternal control apparatus sets up ID automatically to two or more plasma monitors.Transmission Data5FH 80H 60H F0H 01H DATA00 CKSDATA00 00H~FFH: ID of a master *1 is set up.*: when you use it by the multi-system, please remove the link input of a master *1 .*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.13.PLE LINKFunctionExternal control apparatus sets up equally PLE between two or more plasma monitors.Transmission DataDFH 80H 60H F1H 03H DATA00 to DATA02 CKSDATA00 00H:PLE LINK ON01H:PLE LINK OFFDATA01 FFHDATA02 FFH