Trinity │Installation and Operation Instructions Tft Series62.0 SPECIFICATIONSTable 2-1 Trinity Tft SpecificationsDESCRIPTION Tft60 Tft85 Tft110 Tft155 Tft175 Tft200 Tft250 Tft300 Tft399CSA Input Modulation 1,4[MBH] 17-60 17-85 21.6-108 31-155 31-175 31-200 31-250 79.8-299 79.8-399DOE Heating Capacity 1,2[MBH] 56 78 99 144 163 185 230 278 380Net I=B=R Rating 1,2[MBH] 48 68 86 125 141 160 199 239 330DOE AFUE 2 [%] 95 95 95 95 95 95 95 94 95.4Water Connections – NPT[in.] 1 (Male) 1-1/4 (Male) 1-1/2 (Male)Gas Connection - NPT, in. ½ (Male) ¾ (Male)Vent/Air-inlet Pipe Diameter[in.] 3 2 or 3 3 4Dimensions H x W x D [in.] 33-3/8 x 19-3/4 x 14-1/2 33-3/8 x 19-3/4 x 18-1/2 36-3/8 x 25-1/4 x 20Approx. Boiler Weightwith Water [lbs] 110 180 250Approx. Boiler WaterContent [Gallons] 3.2 4.9 6.4Electrical Rating 120V/1Ph/60Hz/less than12ANotes:1 Listed Input and Output ratings are at minimum vent lengths at an altitude of 0-2000ft. Numbers will be lower withlonger venting and/or altitudes greater then 2000ft.2 Ratings based on standard test procedures prescribed by the U.S. Department of Energy; certified by AHRI. Tft399efficiency represents Thermal Efficiency (AFUE is not applicable).3 Trinity Tft requires a special venting system, use only vent materials and methods detailed in these instructions.4 When operating with Propane models Tft60, Tft85 and Tft110 have min/max Input Modulation rates of 17/65, 17.6/88and 22.6/113 MBH respectfully.Wall mounting of unit requires two people to lift the boiler into place. Failure to followthese instructions may result in property damage or personal injury.High Altitude OperationThe Trinity is designed to operate at its maximum listed capacity in installations located at 0-2000ft above SeaLevel. Since the density of air decreases as elevation increases, maximum specified capacity should be de-ratedfor elevations above 2000 ft [610 m] in accordance with Table 2-2.Table 2-2 De-rate % for High AltitudesElevations 2001 ft [610 m] 3000 ft [914 m] 4000 ft [1219 m] 4500 ft [1372 m] 5000 ft [1524 m]In Canada 1 de-rate by 10% de-rate by 10% de-rate by 10% de-rate by 10% de-rate % may varyIn USA 2 - de-rate by 4% de-rate by 8% de-rate by 8% de-rate by 12%Notes:1 Canada: Altitudes between 2000-4500 ft [610-1372 m], de-rate by 10%. Consult local authorities for de-ratingcapacities for altitudes above 4500 ft [1372 m].2 USA: De-rate capacity by 4% for every 1000 ft [305 m] over 2000 ft [610 m].Combustion – At elevations above 2000 feet, the combustion of the boiler must bechecked with a calibrated combustion analyzer to ensure safe and reliable operation. It isthe Installers responsibility to check the combustion and to adjust the combustion in accordance withSection 9.0. Failure to follow these instructions may result in property damage, serious injury, or death.