4. NKD1 SYSTEM INSTALLATION4.2 Control Unit Installation• The NKD1 Control Unit has an Ingress Protection Rating of IP23 enabling it to be installed outdoors.Regulations require that the Control Unit shall be installed outside the pool zone. The Control Unitshall be installed according to AS/NZS 3000 wiring rules.• The Control Unit should be installed in a well ventilated position ideally away from sunlight andrain to prolong life and at least 1m above ground to prevent run off water entry.• Ensure that the Control Unit is not stored near chemicals, fertilisers or in a closed unventilatedshed with similar products as the fumes will cause excessive corrosion and damage to the internalsof the Control Unit and may void warranty.• When mounting the Control Unit on a post it is recommended to install a at panel at least thesame size to act as a waterproof backing plate.• Mount the Control Unit with the Wall Mounting Bracket, Green Plugs and Screws provided.The Control Unit should be mounted no further than 1.5 metres from the Housing for ease ofoperation.4.1 Installation DiagramOXI & ION CELLFILTERPUMPPOWERCONTROL UNIT(Ensure good ven la on)RETURNTO POOLFROMSKIMMER BOXWARNING: DO NOT plug in if carton has been wet.www.naked-pools.com8