A. Connect the gas flex lines and the pilot lineto the gas bulkheads located under the valveaccess opening. Be sure to match up the gasmanifold marked with a painted dot with thecenter bulkhead, also marked with a painteddot. Care must be taken to ensure the pilotline isn’t damaged and ensuring gas tightconnections are made.GasBulkheadsPaintedDotsPilotBulkheadPilotElectrodeLeadsPilotElectrode2.3 bulkheadsSee ThruWindowOrificeVenturiTubeB. Connect the pilot electrode leads to thebulkhead matching the 1/4” flag with the 1/4”bulkhead spade and the 3/16” flag with the3/16” spade.C. Ensure the 2 venturi tubes are over the orificesbefore lighting.D. Check for gas leaks by brushing on a soapand water solution. Do not use open flame.E. After leak test has been performed reinstallaccess panel with gasket.2.4 night light™ installationThe HD81-1 comes equipped with two “Night Lights™”. The lights have been pre-wired and are controlled fromthe remote control.If in the event the lamps or lens need replacing, follow the instructions below:A. Shut off breaker at main power supplyB. Remove the four screws that secure the lens frame to the firebox sides. This frame retains the glass lens.C. The lamp can now be accessed.The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp and lens are special “hightemperature” products. When re-installing, ensure integrity of gasket seal.THE FIREBOX MUST BE SEALED.Over tightening the screws could break the lens. “Light Leakage” from the holes in the housing lamp may beobserved. The holes in the lamp housing are necessary for ventilation and must not be covered.GASKETLENSFRAMECOLOURED SIDE UPJOINTD’ÉTANCHÉITÉLENTILLECADRECÔTÉ COLORÉAU-DESSUSNIGHT LIGHTSBulkhead covers need to be removed.note:Do not handle the lamp (bulb) with bare fingers, protect with a clean, dry cloth.note:ENW415-0713 / E / 05.10.183installation