8W415-0764 / 03.29.102.5 RATING PLATE LOCATION1400 1400L 1402LISTED SOLID FUEL BURNING FIREPLACE INSERT /ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉTESTED TO / TESTÉ SELON :ULC S628 / UL 1482FROM HEATER / DU POÊLERESIDENTIAL / RÉSIDENTIEL140012IN/PO (305 mm)12IN/PO (305 mm)6IN/PO (150 mm)USING DOUBLE WALL CONNECTOR/UTILISATIOND’UN CONDUIT DE RACCORDEMENT À MAISON / MOBILE HOME*1400 140010IN/PO (254 mm) 10IN/PO (254 mm)6IN/PO (152 mm) 6IN/PO (152 mm)4IN/PO (102 mm) 4IN/PO (102 mm)EPI 1402REFERENCE #15982INSTALL AND USE ONLY INACCORDANCE WITH THEMANUFACTURER’SINSTRUCTIONS AND LOCALBUILDING CODES.MINIMUM CEILING HEIGHT:7FT (2.13m)HEARTH EXTENSION /COMBUSTIBLE FLOORPROTECTION: IF INSTALLEDON A COMBUSTIBLE FLOOR,UNIT MUST BE PLACED ON ANON-COMBUSTIBLE FLOORPROTECTOR EXTENDING 18”(455mm) IN FRONT AND 8”(205mm) TO THE SIDES ANDBACK.CHIMNEY TYPE: MINIMUM 6”(152mm) DIAMETERAPPROVED RESIDENTIALTYPE FOR MOBILE HOMEUSE A CHIMNEY LISTED TOULC S629 IN CANADA OR UL103HT IN THE USA.CHIMNEY CONNECTOR: 6”(152mm) DIAMETER MINIMUM24 GAUGE STEEL MINIMUMCLEARANCE FROMHORIZONTAL CONNECTORAND CEILING 18” (455mm).DO NOT OBSTRUCT SPACEUNDER HEATER.SPECIAL METHODS AREREQUIRED WHEN PASSING ACHIMNEY THROUGH A WALLOR CEILING. SEE INSTRUC-TIONS AND BUILDINGCODES.DO NOT CONNECT THIS UNITTO A CHIMNEY FLUESERVING ANOTHERAPPLIANCE.FUEL: FOR USE WITH WOODONLY. DO NOT USE GRATEOR ELEVATE FIRE. BUILDWOOD FIRE DIRECTLY ONHEARTH.WARNING: RISK OF SMOKESPILLAGE. OPERATE ONLYWITH DOOR FULLY CLOSED.REPLACE GLASS ONLY WITHCERAMIC GLASS.DO NOT OVERFIRE. IFHEATER OR CHIMNEYCONNECTORS GLOW, YOUARE OVERFIRING. INSPECTAND CLEAN CHIMNEYFREQUENTLY. UNDERCERTAIN CONDITIONS OF USECREOSOTE BUILD-UP MAYOCCUR RAPIDLY.OPTIONAL BLOWER KIT:EP-62, 115V, 60HZ, 0.82AMP.ROUTE CORD AWAY FROMUNIT.DANGER: RISK OFELECTRICAL SHOCK.DISCONNECT POWERBEFORE SERVICING UNIT.INSERT: INSTALL AND USEONLY IN SOLID FUELBURNING FIREPLACES. DONOT REMOVE BRICKS ORMORTAR FROM SOLID FUELBURNING FIREPLACE.INSTALL WITH A POSITIVEFLUE CONNECTOR ANDFACEPLATE.POUR INSTALLATION ETUTILISATION CONFORMÉMENTAUX INSTRUCTIONS DUFABRICANT ET AUX CODESLOCAUX DU BÂTIMENT.HAUTEUR DE PLAFOND MINIMAL7PI (2,13m).PROLONGEMENTD’ÂTRE/PROTECTION DUPLANCHER COMBUSTIBLE: SIINSTALLÉ SUR UN PLANCHERCOMBUSTIBLE, L’APPAREIL DOITÊTRE PLACÉ SUR UNE PLAQUEPROTECTRICE INCOMBUSTIBLES’ÉTENDANT SUR 18” (455mm) ÀL’AVANT ET 8” (205mm) À L’ARRIÈREET SUR LES CÔTÉS.TYPE DE CHIMNÉE: DIAMÈTREMINIMAL DE 6” (152mm)APPROUVÉE POUR USAGERÉSIDENTIEL. MAISON MOBILEEMPLOYEZ UNE CHEMINÉEHOMOLOGUÉE ULC S629 AUCANADA OU UL 103HT AUXÉTATS-UNIS.RACCORD DE CHEMINÉE:DIAMÈTRE DE 6” (152mm) D’ACIERDE CALIBRE 24 MINIMUM. 18”(455mm) DE DÉGAGEMENTMINIMAL ENTRE LE RACCORDHORIZONTAL ET LE PLAFOND.NE RIEN ENTREPOSER SOUSL’APPAREIL.DES MÉTHODES SPÉCIALES SONTREQUISES LORSQU’UNECHEMINÉE TRAVERSE UN MUR OUUN PLAFOND. VOIR LESINSTRUCTIONS ET LES CODES DUBÂTIMENT.NE PAS RACCORDER À LACHEMINÉE D’UN AUTRE APPAREIL.COMBUSTIBLE: POUR USAGEAVEC LE BOIS SEULEMENT.N’UTILISEZ PAS DE CHENET OU NESURÉLEVEZ PAS LE BOIS.PRÉPAREZ LE FEU DIRECTEMENTSUR L’ÂTRE.AVERTISSEMENT: RISQUED’ÉCHAPPEMENT DE FUMÉE.TENIR LA PORTE FERMÉELORSQUE LE POÊLE FONCTIONNE.REMPLACEZ LA VITRE PAR UNEVITRE EN CÉRAMIQUE SEULEMENT.NE SURCHAUFFEZ PASL’APPAREIL. SI L’APPAREIL OU LESRACCORDS ROUGEOIENT,L’APPAREIL SURCHAUFEE.INSPECTEZ ET NETTOYEZ LACHEMINÉE FRÉQUEMMENT. DANSCERTAINES CONDITIONS, DESDÉPÔTS DE CRÉOSOTE PEUVENTSE FORMER RAPIDEMENT.SOUFFLERIE OPTIONNELLE:EP-62, 115V, 60HZ, 0,82A. TENEZ LECORDON ÉLECTRIQUE LOIN DEL’APPAREIL.DANGER: RISQUE DE SECOUSSEÉLECTRIQUE. DÉBRANCHEZ AVANTDE PROCÉDER À L’ENTRETIEN.ENCASTRÉ: INSTALLEZ ET UTILISEZSEULEMENT DANS UN FOYER ÀCOMBUSTIBLE SOLIDE. NERETIREZ PAS DE MORTIER, NIBRIQUES DU FOYER À COMBUS-TIBLE SOLIDE.INSTALLEZ AVEC UNE GAINECONFORME ET UNE PLAQUE DERECOUVREMENT.CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS ANDINSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USEIN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). AMINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BEREQUIRED BY THE AUTHORITY HAVING JURISDICTION.RENSEIGNEZ-VOUS AUPR ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DUSERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONSD’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTREINSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNEPRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANTJURIDICTION.8" 8"18"8"ALCOVEA"B"CBACK WALL (M/A)45°SIDE WALL (M/L)BACK WALL (M/A)SIDE WALL (M/L)BAIF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BEPLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THATEXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18”(455mm) TO THE FRONT.SI LE POÊ LE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉSUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSERLES CÔTÉS ET L’AMÉRE DU PO Ê LE DE 8” (200mm) ET SE PROLONGER DE 18”(455mm) SUR LE DEVANT.MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALLCHIMNEY CONNECTOR / DÉGAGEMENTS MINIMAUX AUX MATÉRIAUXCOMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:* MODEL 1400 MAY BE INSTALLED INTO A MOBILE HOME OR COMBUSTIBLEALCOVE USING LISTED DOUBLE WALL CONNECTOR. MODEL 1400 MAY BEINSTALLED INTO A MOBILE HOME IN THE UNITED STATES ONLY>* MODÈLE 1400 PEUT ÊTRE INSTALLÉ DANS UNE MAISON MOBILE OU DANSUNE ALCÔVE COMBUSTIBLE EN UTILISANT UN CONDUIT DE RACCORDE-MENT À DOUBLE PAROI CERTIFIÉ. LE MODÈLE 1400 NE PEUT ÊTREINSTALLÉ QUE DANS UNE MAISON MOBILE AUX ÉTATS-UNIS SEULEMENT.DOUBLE PAROICEILING / PLAFONDCD BAFLOOR / PLANCHERHOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSEQUAND L’APPAREIL FONCTIONNE, L A SURFACE DEVIENTCHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LESVÊTEMENTS ET LES MEUBLES À L’ÉCART T. LE CONTACT PEUTCAUSER DES BRÛLURES À LA PEAU.CAUTION:ATTENTION :U.S. ENVIRONMENTAL PROTECTION AGENCY Certifié conforme à la norme d’émanation de particules de juillet 1992.W385-0401_DMADE IN CANADA BY / FABRIQUÉ AU CANADA PAR:WOLF STEEL LTD., BARRIE, ONTARIO, CANADADATE CODE / DE DATEEPA1400SKIN BURNS.CLEARANCES TO COMBUSTIBLE CONSTRUCTION /D ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)A SIDE FACING / CÔTÉ 1 IN/PO (25mm)*B TOP FACING / DESSUS 28 IN/PO (710mm)C MANTEL / TABLETTE 28 IN/PO (710mm)D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)*CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AUBORD DE LA FAÇADELISTED SOLID FUEL BURNING SPACE HEATER /POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉMODEL / MODÈLE - EPA 1400TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92)14501400 SERIES RATING PLATE ILLUSTRATEDFor rating plate location, see“INSTALLATION OVERVIEW”section.