7W415-0713 / A / 11.09.10Air Shutter Openings both BurnersLP 7/16”NG 3/16”2.9 VERMICULITE33.1Sprinkle vermiculite around the charcoal embers.NOTE: Vermiculite is not to be placed on the burner.2.10 GLOWING EMBERSTear the embers into pieces and place along the front row of ports covering all of the burner area. Care shouldbe taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs willglow. The ember material will only glow when exposed to direct flame; however, care should be taken to notblock the burner ports.Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. Phazer™logs glow when exposed to direct flame. Use only certified “glowing embers” and Phazer™ logs available fromyour Authorized dealer.3.0 ADJUSTMENT3.1 FLAME CHARACTERISTICS3.2 VENTURI ADJUSTMENTIt’s important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustra-tions provided. If any flames appear abnormal call a service person. 3/8” - 1/2”PILOTBURNERFLAME MUST ENVELOPUPPER 3/8” TO 1/2” OFFLAME SENSORFLAMESENSORELECTRODE54.1This appliance has an air shutter that has been factory set open accordingto the chart below:Regardless of venturi orientation, closing the air shutter will cause a moreyellow flame, but can lead to carboning. Opening the air shutter will cause amore blue flame, but can cause flame lifting from the burner ports. Theflame may not appear yellow immediately; allow 15 to 30 minutes for thefinal flame color to be established.AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIEDINSTALLER!AIRSHUTTEROPENINGVENTURIBURNERORIFICE49.1