NOTE: Leave enoughwire so that the logset can be removedfrom the enclosurewithout disconnectingthe power supply.A. Remove the securing screw from the electrical cover plate, located on the rear of the log set.B. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.C. Separate the black, white and green wires that have the wire nuts on them.D. Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of thepower supply. Connect the white wire from the unit to the white (neutral) wire from the powersupply. Connect the green wire to the ground wire.E. Resecure the cover plate.BLACKWHITE BLACKWHITE4611-:108&3+6/$5*0/'*3&1-"$&GREENGREEN(L1)(N)(G)WIRE NUTENW415-1461 / 06.25.1510GREENBLACKWHITEHARD WIRING CONNECTIONIf it is necessary to hard wire, a qualified electrician must remove the cord connection, and wire directly to thehousehold wiring. The wire and power supply breaker must be rated for 120V and a minimum of 15 Amps.This log set must be electrically connected and grounded in accordance with local codes, if hard wired. In theabsence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the currentANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.! WARNINGTURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICEPERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.GREENBLACKWHITENOTE: There are 3 wires from the fi replace junction; white (neutral), black (power L1) and green(ground) that connect to 120V power supply (breaker panel), see below.White, Green andBlack wires:Connect to 120Vpower supply.3.2 HARD WIRING INSTALLATIONNOTE: It is recommended tosecure the log set after hardwiring, refer to "SECURINGTHE LOG SET" section.