5www.napoleongrills.comLeak Testing InstructionsWARNING! A leak test must be performed annually and each time a cylinder is hooked up or if a partof the gas system is replaced.WARNING! Never use an open flame to check for gas leaks. Be certain no sparks or open flames are inthe area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to property,serious bodily injury, or death.Leak testing: This must be done before initial use, annually, and whenever any gas components are replacedor serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak TestingDiagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,manifolds and valves.Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommendedby the Napoleon Customer Care department and have the grill inspected by a certified gas installer.If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspectedby a certified gas installer or dealer. Do not use the grill until the leak has been corrected.Technical DataThe following table lists input values for the appliance.Burner Orifice Size (Gross) Heat Input (Total) Gas Usage (Total)I II I IIMain 1.04mm (59) 1.51mm (53) 16 kW 1160 g/hr 1520 L/hrBack 1.51mm (53) 2.26mm (43) 8 kW 580 g/hr 760 L/hrSide* 1.02mm (60) 1.45 mm 3.7 kW 268 g/hr 352 L/hrTotal of all burners which can be operated simultaneously 19.7 kW 1428 g/hr 1872 L/hr RSIB16 kW 1160 g/hr 1520 L/hr RB* RSIB unit onlyCertified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the tableabove. The grill is equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5 mbarfor propane/butane and 18.5 mbar for natural gas and must not be modified or adjusted. For replacement, useonly the regulator specified by the manufacturer.Gas Category I3B/P(30) I3+(28-30/37) I3B/P(37) I3B/P(50) I2H I2E I2E+ I2LOrifice Sizes(seeabove)I I I I II II II IIGases / Pressures Butane andPropane at30mbarButane 28-30mbarPropane 37mbarButane andPropane at37mbarButane andPropane at50mbarG20 at20mbarG20 at20/25 mbarG20/G25 at20/25 mbarG25 at25mbarCountries BE, BG, CY,DK, EE, FI,FR, GB, HR,HU, IS, IT, LT,LU, MT, NL,NO, RO, SE,SI, SK, TRBE, CH, CY, CZ, ES,FR, GB, GR, IE, IT,LT, LU, LV, PT, SK, SIPL AT, CH, DE, SK AT, BG, CH,CZ, DK, EE,ES, FI, GB,GR, HR, HU,IE, IS, IT, LV,LT, NO, PT,RO, SE, SI,SK, TRDE, LU, PL BE,FR NL