Chapter 3 VXIpc 800 Series Configuration and Installation© National Instruments Corporation 3-13 VXIpc 800 Series User ManualEthernet Power-On DefaultsThe VXIpc-800 Ethernet circuitry loads its power-on settings from anEEPROM. You should not change switch S1 from its default setting;however, the switch setting required to do so is included in Figure 3-14for informational purposes.Figure 3-14. Ethernet Power-On DefaultsInstalling the VXIpc 800 SeriesThis section contains general installation instructions for theVXIpc-800. Consult your VXIbus mainframe user manual or technicalreference manual for specific instructions and warnings.1. Plug in your mainframe before installing the VXIpc-800. Thepower cord grounds the mainframe and protects it from electricaldamage while you are installing the module.Warning: To protect both yourself and the mainframe from electrical hazards,the mainframe should remain off until you are finished installing theVXIpc-800 module.2. Remove or open any doors or covers blocking access to themainframe slots.3. If you are installing the VXIpc-800 into a D-size mainframe, installa support designed for installing C-size boards in D-sizemainframes. The VXIpc-800 has no P3 connector and cannotprovide P3 Slot 0 control to VXI devices requiring this capability.Caution: If the VXIpc-800 is not configured for automatic Slot 0 detection, becertain that the slot you select in your VXIbus mainframe matches theVXIpc-800 configuration as either a Slot 0 device or a Non-Slot 0 device.If you install your VXIpc-800 into a slot that does not correspond with thejumper setting, you risk damage to the VXIpc-800, the VXIbus backplane,or both.S1S1a. Ethernet Power-On DefaultsLoaded from EEPROMb. Hardwired Ethernet Values!