Appendix A Specifications© National Instruments Corporation A-3 NI PXI-8105 User ManualShock and VibrationOperational shock .................................. 30 g peak, half-sine, 11 ms pulse(Tested in accordance withIEC-60068-2-27. Test profiledeveloped in accordance withMIL-PRF-28800F.)Random vibrationOperating ........................................ 5 to 500 Hz, 0.3 grms(with solid-state hard drive)Nonoperating .................................. 5 to 500 Hz, 2.4 grms(Tested in accordance withIEC-60068-2-64. Nonoperatingtest profile exceeds therequirements ofMIL-PRF-28800F, Class 3.)SafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use:• IEC 61010-1, EN 61010-1• UL 61010-1• CAN/CSA-C22.2 No. 61010-1Note For UL and other safety certifications, refer to the product label or toni.com/certification, search by model number or product line, and click theappropriate link in the Certification column.Electromagnetic CompatibilityEmissions ............................................... EN 55011 Class A at 10 mFCC Part 15A above 1 GHzImmunity................................................ EN 61326:1997 + A2:2001,Table 1EMC ....................................................... CE, C-Tick, and FCC Part 15(Class A) compliantNote For full EMC compliance, operate this device with shielded cabling.