Appendix E SCXI-1163 Cabling© National Instruments Corporation E-15 SCXI-1163 User Manual50-PinConnectorGroundingScrewThumbscrew CutoutStep 1Step 2Insert Screwdriver inGroove and Rotate toPry OpenFigure E-5. Cover RemovalSCXI-1302 InstallationFollow these steps to install the SCXI-1302:1. Install an SCXI-1180 feedthrough panel as described in the SCXI-1180 Installation section.2. Wire the terminal block as previously described in the SCXI-1302 Wiring Procedure section.3. Connect the SCXI-1302 terminal block to the front panel connector on the SCXI-1180feedthrough panel. Be careful to fit the thumbscrews in the thumbscrew cutouts.4. Tighten the top and bottom captive screws on the back of the terminal block into the screwholes in the front panel to hold the SCXI-1302 securely in place.Check the installation.SCXI-1351 One-Slot Cable ExtenderThe SCXI-1351 cable extender is a miniature SCXI-1340 cable assembly. Instead of connectingto an MIO board 1 m away, the SCXI-1351 female rear connector connects to a male breakoutconnector that must be in the rear connector space of the slot to the left. The SCXI-1351 has afemale mounting bracket connector that mates with the rear signal connector of a module, andalso has a male breakout connector on the ribbon cable for connecting to a feedthrough panel ormore cable extenders, or for connection to an NB5 cable for use with a DIO-96 or anAT-MIO-16D.