Nature Air RGRM-04*MAES Installation Instructions Manual
Contents
|
2” Standard/Concentric RXGY-D02/RXGY-D02A/RXGY-E03A/RXGY-G02 50 40Alternate RXGY-D02/RXGY-D02A 40 3060,0003” Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 50 40Alternate RXGY-D03/RXGY-D03A 50 40Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 50 4075,000 3” Alternate RXGY-D03/RXGY-D03A 50 40Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-D03A/RXGY-G02 50 4090,000 3” Alternate RXGY-D03/RXGH-D03A 50 40Standard/Concentric RXGY-D03/RXGY-D03A/RXGH-E03A/RXGY-G02 50 40105,000 3” Alternate RXGY-D03/RXGY-D03A 50 4023DIRECT VENTINSTALLATIONSREAD AND FOLLOW ALLINSTRUCTIONS IN THIS SECTION.FAILURE TO PROPERLY VENTTHIS FURNACE CAN CAUSECARBON MONOXIDE POISONINGOR AN EXPLOSION OR FIRE,RESULTING IN PROPERTYDAMAGE, PERSONAL INJURYOR DEATH.Direct vent installations require adedicated combustion air and ventingsystem. All air for combustion is takenfrom the outside atmosphere and allcombustion products are discharged tothe outdoors. Therefore, noventilation or combustion airopenings are required.IMPORTANT: The plastic combustionair and venting components are ofSchedule 40 PVC. If using ABS pipingensure that the solvent cement iscompatible for joining PVC to ABScomponents or use a mechanicalconnection that can withstand the venttemperatures and are corrosionresistant.INSTALLATION GUIDELINESAll exhaust piping must be installed incompliance with Part 7, “Venting ofEquipment,” of the latest edition of theNational Fuel Gas Code NPFA54/ANSI Z223.1-, local codes orordinances and these instructions.1. Vertical piping is preferred.2. All horizontal piping must slopeupward a minimum of 1/4 inchper foot of run so that condensatedrains toward the furnace.3. All horizontal runs must besupported at least every 4 feet.No sags or dips are permitted.4. IMPORTANT: Do not commonvent with any other appliance. Donot install in the same chase orchimney with a metal or hightemperature plastic pipe fromanother gas or fuel-burningappliance unless the requiredminimum clearances tocombustibles are maintainedbetween the PVC pipe and otherpipes. Minimum 3 ft. clearancerequired between combustion airinlet and any other exhaust.5. For horizontal runs where watermay collect, wrap the vent pipewith self-regulating 3 or 5 wattheat tape. The heat tape must beU.L. listed and installed per themanufacturer’s instructions.6. The minimum, pipe length is5 feet for combustion air andexhaust.7. Do not install elbows back toback. Allow at least 15” betweenelbows.Size the exhaust and combustion airintake pipes as specified in Tables 3and 4. These tables list the maximum! WARNINGStandard/Concentric RXGY-D02/RXGY-D02A/RXGY-E03A/GXGY-G02 50 4045,000 2” Alternate RXGY-D02/RXGY-D02A 50 40Standard/Concentric RXGY-D02/RXGY-D02A/RXGY-E03A/RXGY-G02 40 352” Alternate RXGY-D02/RXGY-D02A 20 1560,0003” Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 60 50Alternate RXGY-D03/RXGY-D03A 50 4075,000 3” Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 45 40Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 50 4090,000 3” Alternate RXGY-D03/RXGY-D03A 40 30105,000 3” Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 45 40Standard/Concentric RXGY-D03/RXGY-D03A/RXGY-E03A/RXGY-G02 45 35120,000 3” Alternate RXGY-D04/RXGY-D04A 40 30FURNACEINPUTPIPESIZE TERMINATION VENT TERMINATIONKIT RECOMMENDED1 - 2 3 - 4NUMBER OF ELBOWS45 or 90 DegreesMedium / Long Radius ONLYTABLE 3UPFLOW UNITS FOR DIRECT VENT APPLICATIONS - AIR FOR COMBUSTIONPROVIDED FROM OUTDOORSMAXIMUM ALLOWABLE LENGTH IN FEET OF EACH EXHAUST PIPE AND INTAKE AIR PIPENOTES:1. N.A. - NOT APPLICABLE2. MAXIMUM OF 4 ELBOWS MAY BE USED. DO NOT COUNT ELBOWS IN ALTERNATE TERMINATION KIT.MEDIUM OR LONG SWEEP ELBOWS MAY BE USED.3. A 45 DEGREE ELBOW IS CONSIDERED ONE ELBOW.4. CONCENTRIC TERMINATION NO. RXGY-E03/RXGY-E03A IS FOR THRU-THE-ROOF OR THRU-THE-WALL VENTING.5. USE KITS RXGY-DO2/D02A (2"), RXGY-G02 (2"), OR RXGY-D03/D03A (3") FOR STANDARD OR ALTERNATETHRU-THE-WALL VENTING.6. USE KITS RXGY-D04/D04A FOR ALTERNATE VENTING OF 120,000 BTUH UNITS WITH LONG RUNS.7. KIT NUMBERS CONTAINING SUFFIX “A” ARE APPROVED FOR INSTALLATION IN CANADA.8. NO SCREENS MAY BE USED TO COVER COMBUSTION AIR AND EXHAUST.TABLE 4DOWNFLOW/HORIZONTAL UNITS FOR DIRECT VENT APPLICATIONS - AIR FOR COMBUSTIONPROVIDED FROM OUTDOORSMAXIMUM ALLOWABLE LENGTH IN FEET OF EACH EXHAUST PIPE AND INTAKE AIR PIPEFURNACEINPUTPIPESIZE TERMINATION VENT TERMINATIONKIT RECOMMENDED1 - 2 3 - 4NUMBER OF ELBOWS22.5, 45 or 90 DegreesMedium / Long Radius ONLYNOTES:1. N.A. - NOT APPLICABLE2. MAXIMUM OF 4 ELBOWS MAY BE USED. DO NOT COUNT ELBOWS IN ALTERNATE TERMINATION KIT.MEDIUM OR LONG SWEEP ELBOWS MAY BE USED.3. A 45 DEGREE ELBOW IS CONSIDERED ONE ELBOW.4. CONCENTRIC TERMINATION NO. RXGY-E03/RXGY-E03A IS FOR THRU-THE-ROOF OR THRU-THE-WALL VENTING.5. USE KITS RXGY-DO2/D02A (2"), RXGY-G02 (2"), OR RXGY-D03/D03A (3") FOR STANDARD OR ALTERNATETHRU-THE-WALL VENTING.6. USE KITS RXGY-D04/D04A FOR ALTERNATE VENTING OF 120,000 BTUH UNITS WITH LONG RUNS.7. KIT NUMBERS CONTAINING SUFFIX “A” ARE APPROVED FOR INSTALLATION IN CANADA.8. NO SCREENS MAY BE USED TO COVER COMBUSTION AIR AND EXHAUST. |
manualsdatabase
Your AI-powered manual search engine