Page 1217. Programming & CommissioningThis section refers to Password Protected sections of the Pellet fire Menus. Only Nature’s Flame approvedpellet fi re installers and technicians will have access to these passwords. If you are not a Nature’s Flameapproved installer or technician, please do not attempt to install, program or commission any pellet fi refrom Nature’s Flame.17.1 Camino Parameters - version BOX 03Name Program Unit Value BeforeProgrammingAfterProgrammingAdjustedSettingsMinutes time out PR01 Min 18Minutes start PR02 Min 5Clean frequency PR03 Min 60Cleaning duration PR04 Sec 20Screw start PR05 Sec 2Screw power 1 PR06 Sec 1.3Screw power 2 PR07 Sec 1.8Screw power 3 PR08 Sec 2.2Screw power 4 PR09 Sec 2.7Screw power 5 PR10 Sec 3.2Re-start threshold PR11 °C 80No pellet threshold PR12 °C 50Off threshold PR13 °C 45Maximum threshold PR14 °C 250Fan threshold PR15 °C 90Smoke ignition PR16 RPM 2100Ignition smoke speed PR17 RPM 19501 smoke speed PR18 RPM 12502 smoke speed PR19 RPM 14503 smoke speed PR20 RPM 16504 smoke speed PR21 RPM 18505 smoke speed PR22 RPM 2050Air 1 speed PR23 V 110Air 2 speed PR24 V 120Air 3 speed PR25 V 130Air 4 speed PR26 V 150Air 5 speed PR27 V 175Enable glow plug PR28 on / off ONSuct smoke cleaning PR29 RPM 2800Screw cleaning PR30 Sec 1.3Pre-heat glow plug PR31 Sec 150Screw max load PR32 Min 5Flame delta PR33 °C 20Screw ignition PR34 Sec 2.2Alarms delay PR35 Sec 60xHZ frequency PR36 Hz 50