AR-SP-AC – SURGE SUPPRESSOR KIT(Requires AR-SP-AC Surge Protector Accessory Kit)STEP 1.Inspect shipping package and contents to ensure no damage hasoccurred during shipping.STEP 2.Open AR Lens with 7mm hex socket driver. Allow Lens to hang viaretention strap.NOTE:Screws are captive fasteners and will remain attached to the Lens for ease ofreinstall and prevent loss of fasteners.STEP 3.Install provided double-sided tape along side of surge protector.Remove backing paper and place between mounting points as shown,with tape-side down. Install retention strap with two M3 fasteners andensure surge protector is held tightly in place.STEP 4.Wire according to wiring instructions on Page 2. Refer to NEC/CECcodes and follow all applicable local standards.STEP 5.Close AR lens. Ensure the retention cable is not pinched between ARHead and the AR Lens. Tighten lens bolts using a 7mm socket or boxwrench to 1.7 N-m (15 in-lbs) in the order designated in the diagram toensure gasket sealing. 567891011121234Step 5AR-SP-AC PART NAMEQTY11122FSP3-277-20KA SURGE PROTECTOR3M VHB TAPESURGE SUPPRESSOR RETENTION STRAPM3 x 8mm PAN HEAD PHILLIPS MACHINE SCREWM3 FLAT WASHERStep 3M3 SCREWThis AR-SP-AC kit is intended for use with UL Listed AR luminaire asmarked on the luminaire nameplate.Accessory Package ContentsINSTALLATION STEPSTMNemaluxI N D U S T R I A L AR-GENrev. A-171-2www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190MADE IN CANADA