— 12 —SpecificationsPower Source ...............................................................................................................................................120 V, 60 HzPower Consumption...........................................................................................................................................65 WattsFan Output ........................................................................................................................................................ 212 CFMTreatment Process .......................................... UVC 254 NM germicidle chambers, UVC 254 nm germicidle chambersUV Lamp Type ....................................................................................................................Carbon filter & twin hydroxylReaction Surface .............................................................................................. 266.90 Square Inches, 25,000 Hour LifeRoom Capacity.....................................................................................................................................2500 Square FeetDimensions .......................................................................................................................8.2 (W) x 10 (D) x 17 (L) inchesWeight ................................................................................................................................................................... 9.5LbsSpecifications subject to change without notice.TroubleshootingUV Lamps not functioning.• The life of the UV bulb may have been met or damaged. If they are burnt out, replace both bulbs as shown on pages 9 to11. If broken, refer to pages 4 and 5 for Handling and Disposal of Mercury.• Internal Component failure; call 1-866-676-9663 for service.Hydroxyl Generator is not performing well.• The life of the carbon filter may have been met or damaged; replace both carbon filters, see page 8.• The life of the UV bulb may have been met or damaged. If they are burnt out, replace both bulbs as shown on pages 9 to11. If broken, refer to pages 4-5 for Handling and Disposal of Mercury.• Internal Component failure; visit www.queenaire.com for service.Hydroxyl Generator not working at all• Unit is not plugged in, or power is not active at the AC socket.• Fuse has blown. Unplug and turn over unit to access fuse. Rotate fuse holder and replace with 2 Amp fuse.• Timer time is up. Press the Power switch to the OFF position and then to the TIMER or CONTINUOUS position.