Page 36/82 PS S ERIES HARDWARE SETUP PROCEDUREHorizontal (PS15R2 only)• Remove the four TORX screws holding connector plates on both side of PS15R2;• Remove the connector plates from PS15R2;• Fill each screw hole with Locktite 243 or equivalent;• Position external plates from VNI-LBRK kits and secure them using the shoulder screwssupplied with these kits;• Position “L” brackets from VNI-LBRK kits, and secure them to the cabinet using the 4 remainingshoulder screws supplied with these kits.• Slings and shackles (not provided) are required to secure the cluster under the ceiling;CABLE SUSPENSION MOUNTING PROCEDURE FOR PS15R27.3.4 PS10R2 and PD15R2 wall suspension (vertical or horizontal)Required itemVertical• 1 VNI-WS10 for PS10R2• 1 VNI-WS15 for PS15R2• 4 x 12mm diameter screws (not provided)Horizontal• 1 VNI-WS10 and 1 VNI-UBRK10 for PS10R2• 1 VNI-WS15 and 1 VNI-UBRK12 for PS15R2• 4 x 12mm diameter screws (not provided)IMPORTANTEnsure that the wall is strong enough to hold PS cabinet weight and that the screws12mm diameter and corresponding plugs required to fix the VNI-WS on the wall areproperly dimensioned.