Nidec Digistart D2 User Manual
7 Technical Data• Mains SupplyMains voltage (L1, L2, L3)D2-14-xxx ............................................................................. 3 x 200 VAC ~ 440 VAC (+ 10% / - 15%)D2-16-xxx ............................................................................. 3 x 200 VAC ~ 575 VAC (+ 10% / - 15%)Mains frequency (at start) .................................................................................................... 45 Hz to 66 HzRated insulation voltage ................................................................................................................ 600 VACForm designation ................................................................ Bypassed semiconductor motor starter form 1• Control voltage (CSH, CSL, CSR)D2-1x-xxx-C1 ............................................................................................... 110-240 VAC (+ 10% / - 15%)or 380-440 VAC (+ 10% / - 15%)D2-1x-xxx-C2 ............................................................................................ 24 VAC /VDC (+ 10% / - 15%)Recommended fuse .......................................................... 1 A continuous (10 A max, 0.01 second surge)Current consumption (during run) ................................................................................................ < 100 mACurrent consumption (inrush) .............................................................................................................. 10 A• InputsStart (terminal DI1) .............................................................................. Normally open, 150 kΩ @ 300 VACStop (terminal DI2) ........................................................................... Normally closed, 150 kΩ @ 300 VACMotor thermistor ...................................................................................................................... Trip > 3.6 kΩ• OutputsMain contactor relay (terminals COM2, RLO2) ..................................................................... Normally open6 A, 30 VDC / 6 A, 250 VAC resistiveProgrammable relay (terminals COM1, RLO1) ..................................................................... Normally open....................................................................................................... 6 A, 30 VDC / 6 A, 250 VAC resistive• EnvironmentalDegree of Protection D2-018 to D2-100 .............................................................................................. IP20Degree of Protection D2-140 to D2-200 .............................................................................................. IP00Operating temperature .................................................................................................... - 10 °C to + 60 °CStorage temperature ..................................................... -25 °C~+ 60 °C (to +70 °C for less than 24 hours)Humidity ........................................................................................................... 5%~95% Relative HumidityPollution degree ............................................................................................................. Pollution Degree 3Vibration ....................................................................................................... IEC 60068 Test Fc Sinusoidal4 Hz to 13.2 Hz: ± 1 mm displacement....................................................................................................................... 13.2 Hz to 200 Hz: ± 0.7 g• EMC EmissionEquipment class (EMC) .................................................................................................................. Class BConducted radio frequency emission ............................................. 0.15 MHz to 0.5 MHz: < 56-46 dB (μV)0.5 MHz to 5 MHz: < 46 dB (μV)5 MHz to 30 MHz: < 50 dB (μV)Radiated radio frequency emission ................................................... 30 MHz to 230 MHz: < 30 dB (μV/m).................................................................................................. 230 MHz to 1000 MHz: < 37 dB (μV/m)• EMC ImmunityElectrostatic discharge ............................................................. 4 kV contact discharge, 8 kV air dischargeRadio frequency electromagnetic field .............................................. 0.15 MHz to 1000 MHz: 140 dB (μV)Rated impulse withstand voltage (Fast transients 5/50 ns) ................ 2 kV line to ground, 1 kV line to lineVoltage dip and short time interruption ................................................... 100 ms (at 40% nominal voltage)Harmonics and distortion ........................................................... IEC61000-2-4 (Class 3), EN/IEC61800-3• Short CircuitRated short-circuit current D2-018 to D2-048 .................................................................................... 5 kA 1Rated short-circuit current D2-060 to D2-200 .................................................................................. 10 kA 11 These short circuit ratings are with fuses used as given in the table under Semiconductor Fuses onpage 11.18 Digistart D2: User GuideIssue: F |
Related manuals for Nidec D2-018
Nidec Digistart D3 User Manual
Nidec Digistart D4 User Manual
Nidec LEROY-SOMER Digistart D5 User Manual
Nidec Digitax HD M753 User Manual
Nidec H300 User Manual
Nidec Unidrive M200 User Manual
Nidec Digitax HD M75X Series Quick Start Manual
Nidec SPDM CONTROL BOX User Manual
Nidec Unidrive M400 series Quick Start Manual
Nidec MCE Motion 2000 Touch Screen User Manual
manualsdatabase
Your AI-powered manual search engine