Niigata seiki BEVEL BOX Instruction Manual
ABSABSABSReference SurfaceABSBEVEL BOX Model No. : BB-180LThank you for purchasing the Bevel Box Digital Angle Meter.Please read this manual thoroughly before use for proper operation.DigitalAngle MeterPrecision angle measurement and workingreference for assembly of machinery, tooling,jigs, etc.Magnetic base.Absolute Mode for measuring angle referencedto true horizontal.0-point can be set at any position in RelativeMode.Hold function to freeze display.Auto Power Off feature. (approx. 5 minutes)This is a precision measurement instrument - Handle WithCare. Do not drop or subject to shock.Instrument accuracy is listed under Specifications section.For applications requiring higher accuracy, please usehigher precision angle gauge.Do not engrave or mark with electric pen.Holding power of magnet will vary depending on workpiece.Test for sufficient holding force before use to insureinstrument does not fall.Keep away from precision instruments, watches, etc. andany devices that can be damaged by magnet.Clean measuring surface with soft cloth after use toremove any debris or contamination.Remove battery if gauge will not be used for a long periodof time.Do not use or store in places subject to extreme temperatefluctuations, direct sunlight, dusty locations, or locationsthat are wet or have high humidity.PARTS IDENTIFICATIONModel± 0.2°0.1°0.1°BB-180L±180.0°approx. 70g (without battery)Measurement RangeResolutionAccuracyRepeatabilityapprox. 545Operating Temperature RangeWeightAAA Battery (1 )PowerBattery LifeAbsolute (ABS), RelativeMeasurement Modesapprox. 40Hr. (for alkaline battery)Accessories Storage CaseAPPLICATIONS and FEATURESSPECIFICATIONSCAUTION[LCD] DisplayRear Battery CoverBottomMeasurement Surface[ZERO] Button[ON/OFF] Button[HOLD] ButtonBatteryCoverAAABatteryFrontINSERTING / REPLACING the BATTERYPush on tab of rear batterycover to open.Insert AAA battery as shownin drawing. Replace cover.To Turn ON PowerWhen power is OFF, press [ON/OFF] Button.To Turn OFF PowerWhen power is ON, long press of [ON/OFF]Button.Auto Power Off FeatureIf there is no change in measured value forapproximately5 min., power will turn OFFautomatically.Absolute Measurement Mode (ABS)When power is ON, press [ON/OFF] button toswitch gauge to Absolute Mode. “ABS” icon willappear on the LCD display.Relative Measurement ModeWhen power is ON, press [ZERO] button toswitch gauge to Relative Mode. The “ABS” iconwill turn off and display will reset to 0.0.LCD DISPLAY (POWER) ON / OFFMEASUREMENT MODETabINSTRUCTION MANUAL1 AAA battery required (not included.)Press [ON/OFF] to turn on power.If “ABS” icon is not displayed, press [ON/OFF] again to switchgauge to Absolute Measurement Mode and display icon.Place the measurement surface of the gauge onto the object to bemeasured. (Figure:2)Direction of tilt icon will display next to measured value -If tilt is to left, icon will display.If tilt is to right, icon will display.A bsolute Measurement Mode (ABS)When Taking Measurements, Please NoteIn Relative Measurement Mode, 0° can be preset at any angle.Press [ON/OFF] to turn on power.Place gauge on reference surface and press [ZERO] button.Figure:3)Place the measurement surface of the gauge onto the object tobe measured. (Figure:4)Direction of tilt icon will display next to measured value -If tilt is to left, icon will display.If tilt is to right, icon will display.Press the [ON/OFF] Button again to switch back to AbsoluteMeasurement Mode.Relative Measurement ModeTilted 10° to leftfrom horizontalTilted 10° to rightfrom horizontalABS ABSTilted 5° to left fromreference surfaceTilted 5° to right fromreference surfaceTAKING MEASUREMENTSNo display.Displayed reading is in error.Displayed value does not change as gauge is moved.If any of the following symptoms appear, please cycle power byremoving and replacing battery, or replacing battery with a fresh one.If problem persists, or if you have any questions, please contact distributoror place of purchase.Please note, manufacturer is unable to respond to inquires or provideservice directly.Please contact distributor or place of purchase.TROUBLESHOOTINGPlace the measurement surface of the gauge onto the object tobe measured. (Figure:1)If off-axis tilt of the gauge (toward front or back sides) exceeds±5°, a measurement can not be taken and "Erro" will be displayedon the LCD.Surface to be MeasuredPress [ZERO] ButtonDisplay reading is 0.0°12(Figure: 1)(Figure: 2)(Figure:3 )(Figure:4 )Press [HOLD] to fix the reading on the display.Press [HOLD] a second time to release.HOLD FUNCTIONNiigata seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jp |
Related manuals for Niigata seiki BB-180L
Niigata seiki N-5AS Instruction Manual
Niigata seiki BB-180A Instruction Manual
Niigata seiki S Series Instruction Manual
Niigata seiki DMS-AE Instruction Manual
Niigata seiki WCDI-6 Instruction Manual
Niigata seiki TVC-60 Instruction Manual
Niigata seiki DP-180 Instruction Manual
Niigata seiki DT-150 Instruction Manual
Niigata seiki TVC-60 Instruction Manual
Niigata seiki VH-30D Instruction Manual
manualsdatabase
Your AI-powered manual search engine