Niigata seiki LS4-150S Assembly Instructions Manual
××SPECIFICATIONSASSEMBLY (cont.)HOW TO USEPART NAMES, DIMENSIONSWARNINGCARE & STORAGE NOTESLED STAND MAGNIFIER4x Magnification lens SL-4Type : White Glass lensMagnification : ~4xViewable diameter : ~φ140mmHead : PolycarbonateBase : Steel~1.8mLens cloth, 3.0mm hex wrenchMagnifying LensMaterialCord LengthAccessoriesRated voltageRated freq.Rated powerLight sourceColor temp.EfficiencyWeightHeightAC100V50/60Hz15W84x white LED~5,000K daylight100lm/W~5.3~430mm2x MagnificationItem No.:SL-2Magnification:~2xViewable area:~φ170mmMakes work easy - Hands free; Well lit; Wide view.LS4-150SRead and Follow for Safe Use of ProductBEFORE USEThank you for purchasing the LS4-150S LED Stand Magnifier.Please read this manual thoroughly before use to insure proper operation andlong service.To prevent electrical shock, always make sure power is OFF before assembly orattaching/detaching lens or cleaning the equipment.Never look at sun or bright light through the lens. There is risk of damage to eyesight.Do not expose lens to sunlight or intense light, there is risk of starting fire.Never leave lens in location where it can be exposed to direct or reflected sunlight.Close the lens cover when not in use in order to prevent starting fire.When installed on a sloped surface the unit may slip causing malfunction, damage, orinjury. Do not install on surface with incline of more than 5 from horizontal.Do not use the power cord for lifting or moving, and never pull on the cord. There is riskof the unit falling, or damage to the cord which may result in injury or fire.CAUTIONHandle with Care. Do not drop, scratch, or use strong force with product. (Use specialcare when cleaning.) Damage to product may cause injury.Do not wash the lens with water. Water in long contact with lens may cause mold orcloudiness.The LED light is capable of frequent on/off cycles, but to avoid wear and damage to theswitch, do not cycle the switch unnecessarily.This product contains metal bearing surfaces and may produce trace amount of dustand powder due to repeated friction on metal surfaces. Therefore, it is not suitable forclean-room applications. If there is concern over exposing workpiece to contamination,do not use for that application or take care not to reposition light while above workpiece.Base Plate surface may scratch table if slid upon it. To prevent damage, place protectivesheet or board under unit to protect the table.Place workpiece on base plate, as moving the lens too far to the side may cause thelight to topple. Do not forcibly move any parts beyond their limits and use care to preventinstability.Please keep lens clean of dust and fingerprints.Clean lens gently with dedicated lens cloth. Do not wash with abrasive cleaners, or rinsewith water.Keep lens protection cover in down position, and unplug power cord when not in use forextended period.Instruction ManualNiigata seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jpHead Joint Range of MotionInsert the Main Post all the way into the hole in the Support.Secure with the Socket Head screw using the 3mm Hex Wrench.Attach the Support Arm; make sure the Head Clamp is orientedpointed down as shown in the diagram.BaseSupport ArmMain PostArm Clampsocket headscrew3.0mm hexwrenchHead ClampHole for Main PostMain Post SupportOrientation○○ ××~80max~30maxHorizontal VerticalHead Clamp××××Never rotate the head towardthe Support Arm beyond thecenter of Lens.For best results, and to preventeye fatigue, adjust the Arm sothat the Lens is parallel to thesurface you wish to inspect,and securely tighten the Clamp.The best lens position willdepend on distance betweeneyes and the workpiece.Plug in the cord and turn on thePower Switch.Position unit so that externallights, such as the ceilingfixtures, are not reflected in thelens.After use, close the LensCover, turn off the PowerSwitch, and unplug the PowerCord.OptionalReplacement Lens:PowerSwitchapprox. 280~410mmSupport ArmHeight : 430mmMain Post CampMain PostPower plugBaseapprox. : W240D400mmLens CoverMain PostSupportLight HeadClampArm ClampViewable area:~φ140mmLensPlease Note: Due to product enhancements, appearanceand specifications are subject to change without notice.ASSEMBLY INSTRUCTIONSASSEMBLYCAUTION: Do not force the joint connecting the Light Head to the Support Armbeyond its range of motion. The joint will fail and create a hazardous condition.When first received, in order to avoid damage please use the following procedureto remove the Light Head from the box and assemble.Careful not to damage the cord, rotate the Support Arm horizontallyin the direction of the arrow.Be careful of the cord while removing from the box.Move horizontallyIt may cause damageDo not lift arm upSupport ArmNote, drawing omits ties,cord, etc. for clarity. Actualpackaging may differ.Videodemonstration!https://youtu.be/uUWNXm8rbmQ |
Related manuals for Niigata seiki LS4-150S
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine