20-25mmCR2032Always use CR2032battery.PLEASE NOTENotchDIGITAL S-LINE 3-POINT MICROMETERThank you for purchasing the DIGITAL S-LINE 3-POINT MICROMETER. Please read this manual thoroughly before usefor proper operation.Ring gauge calibration standard (not included) is required for zero setting. Please prepare ring gauge appropriate for theinstrument’s measurement range.INSTRUCTION MANUALEasy to read digital display.High accuracy 3-point ID measurements.Capable of storing up to three preset values.With tolerance setting capability.Auto display off function (approx. 4 hrs.)FEATURESSPECIFICATIONSResolution:0.001mmAccuracy:4 mOperating Temperature Range:1540Storage Temperature Range:050Electronic Unit Waterproof Grade:IP65 Spec.Power:CR2032 (Lithium Battery)1x included for testingGauge HeadRod[SET] Button[MODE] ButtonLCD Display (side)Probe TipsBattery Cover Ratchet StopConstant Force MechanismPART IDENTIFICATIONREPLACING THE BATTERYACCESSORIESCR2032 (Lithium Battery)Driver for battery replacementProvided for testing.Please replace with newbattery before use.4 1Press and hold the [MODE] button and[SET] button simultaneously to changethe number of digits displayed to theright of the decimal point, and thedirection of increasing display value.The options are represented as:0.001/ 0.01 /-0.001 / -0.01 on thedisplay for the available choices.Always allow sufficient time for instrument and object to be measured to reach the same temperature before takingmeasurement.Always remove dirt from measuring surfaces with a lens cloth before use.Keep instrument away from direct sunlight or high temperatures such as in a car, or near a stove or heat source.Do not turn ratchet stop above or below measurement range.When low battery indicator is displayed, please replace battery as soon as possible. Continued use may cause readingerrors.This is a precision instrument, handle with care. Do not drop or subject to excessive forces.Remove dust and cutting chips after use and apply rust preventative oil to metallic surfaces. Please keep out of reachof children.Please do not use organic solvents to clean the instrument body.Please do not disassemble or modify.Only use as directed. Improper use may cause accident or injury.CAUTION (Ring gauge not included.)Using accessory driver, remove the two batterycover screws. A flat-head driver can be used in thenotch to gently pry open the cover. Pull out the batterycover.Insert the new battery following the marks on thebattery cover.Replace the cover and tighten the screws.When battery level is low,indicator will display on the LCD. Withcontinued use, the display will becomeunstable and readout may not becorrect. The battery cover screwsare very small, care must betaken to prevent loss.Use care not to bend the terminalswhen inserting the battery.CONTROLLING READOUT DIGITS AND POLARITYBBRemove any grease and dust from the measuring surfaces with a cleancloth, such as a lens cleaning cloth. Make sure no foreign objects areadhered to the surfaces.Turn on power and make sure measurement screen is displayed.Insert the measurement head into object to be measured and turn spindleuntil the measuring surfaces make contact with the inside diameter.Continue turning until ratchet stop clicks 1 3 times and read themeasurement off the LCD display.OPERATIONSETTING SCREEN MEASUREMENT SCREENPress andHold BothButtons atSame Time[SET]Button[MODE]ButtonMeasurement Range(mm)Measuring PartMaterialCarbide TipAlloy Steel TipBatteryNotchMCD-0608IPSMCD-0810IPSMCD-10125IPSMCD-12516IPSMCD-1620IPSMCD-2025IPSMCD-2535IPSMCD-3550IPS681012.51620253581012.51620253550Model No. : MCD-****IPS Niigata seiki Co., Ltd.6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-31-5660 Fax. : +81-256-39-7730MAIL:intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jpI221-K 1411Value displayed forspreading gauge headIncreaseDecreaseIncreaseDecreaseObject To Be Measured20-25mm“Click, Click”Inser t