Niigata seiki WTI Series User Manual
- 1 - - 2 -- 3 - - 4 -Direction ofMeasurement Direction ofMeasurementDirection ofMeasurement Direction ofMeasurementWorkpiece WorkpieceWorkpiece Workpiece90 90PART IDENTIFICATION, FUNCTIONProbe (Stylus)BezelPointer(Needle)Model WTI-8030S shownScale plateReplacement Probe Part No. : WTI-2030SWTI-2038SWTI-20SWTI-2030RWTI-2038RWTI-20RWTI-2030WWTI-2038WWTI-20WWTI-8030SWTI-8038SWTI-80SWTI-8030RWTI-8038RWTI-80RWTI-8030WWTI-8038WWTI-80WMounting ExampleRotate to loosenDovetailsStem(φ6φ 8mm)Spanner (for Probe)[Accessories]Dovetail grooveMounting bracketDovetails DovetailMinimize LengthGauge HolderSupport ArmStemMountingbracketInsertInsertInsert (φ6φ8mm )WTI-2030SWTI-2030RWTI-2030WWTI-2038SWTI-2038RWTI-2038WWTI-8030SWTI-8030RWTI-8030WWTI-8038SWTI-8038RWTI-8038WSteel BallRubyCarbide BallSteel BallRubyCarbide BallSteel BallRubyCarbide BallSteel BallRubyCarbide Ball0.0020.0020.010.010~0.20~0.20~0.80~0.80-100-00-100-00-40-00-40-0661313223311334410100.50.50.50.5Model No. Scale Weight(g)Graduation(mm)MeasurementRange(mm)Wide-rangeAccuracy(m )RetraceError(m )MeasuringForce(N)Repeatability(m )Adjacent Error(m ) Probe70807080Ex.) Reference Part 30mm Gauge Block : 30mmWorkpiece height : 30.08mmSet origin with Reference Part Measure workpiecePointerScale plate BezelSpannerSlot TightenLoosenReplacing ProbePlease use Spanner supplied with gauge.ScrewAdjusting Length After Changing ProbeWTI-2030S WTI-2038S WTI-2030RWTI-2038R WTI-2030W WTI-2038W onlyRotate Probe to expose screw as shown.Using a screwdriver, turn screw andadjust Probe length.Thank you for purchasing the Niigata Seiki Dial Indicator.Used with a Magnetic Base or Indicator Stand, this gauge will show the difference in height or positionrelative to a zero point set at a reference position.Model No.User ManualWTI-PROFESSIONALDIAL INDICATORDial Indicator / ComparatorAPPLICATIONS Tight places where plunger type Dial Gauge can not be used.Use on milling machines and laths for centering, measure runout, parallelism,flatness, etc.Mount on height gauge for various measurements.SAFETY NOTIFICATIONSThroughout this manual, symbol indicatesRISK OF PERSONAL INJURY OR PROPERTYDAMAGE if not followed.The symbol indicates something which isPROHIBITED, and the symbol IndicatesREQUIRED step or necessary condition.For safe and proper use of this product, please read thisinstruction manual before use and follow the proceduresdescribed. Please keep manual where it is accessible touser for future reference.Keep this manual with the instrument if transferred orleased to a third party.For inquiries about this product, please contact dealer orNiigata Seiki at the address listed on the following page.Pointer Shows measurement on the Scale PlateScale plate Graduation. Turn Bezel to rotateProbe Feeler which contacts workpieceBezel Rotate to turn Scale PlateDovetails For attaching StemStem For mounting to HolderMounting bracket Connects Stem to gaugeDovetail groove Matches Dovetail in gauge body for mounting StemSpanner Tool to change ProbeSAFETY PRECAUTIONSWARNING Indicates risk of personal injury or property damage if not followed.Please ObserveAlways follow the procedures specified below in order to prevent harm to yourself or others, and toprevent damage to property.Content marked as follows indicates risk of injury or damage if not followed.CAUTIONDenotes a prohibition – You MUST NOT do Denotes a requirement – You MUST doThese symbols mark content that must be observed.Read the manual and follow all instructions.Use of product other than as described in themanual may cause accident.Use only as indicator Gauge.Use for any purpose other than measuringmay damage or wear the instrument.Improper use may also cause accident.Use in an environment which meets thefollowing conditions:Temperature within range of 0~40 Chumidity 30~70% (non-condensing.)Location with minimal dust, oil, oil mist,and protected from direct sunlight.Location protected from use by childrenand unauthorized people.Use in location contrary to the above maycause poor accuracy, damage to the product,or may result in accident or injury.Handle With Care.Do not drop or subject to shock, do not placeunder heavy objects. Damage may causefailure or poor accuracy.Do not disassemble or modify.It may damage Gauge and cause pooraccuracy.If Bezel Clamp Screw is removed, internalcomponents may come loose and becomemisaligned causing product failure.Do not shock Probe.Rapid motion, or lateral force may damageGauge and cause poor accuracy.Measurement DirectionPREPARATION - MountingDial Indicator must be securely mounted such as on a comparator stand or magnetic base.Please follow these guidelines.Make sure Gauge holder is rigid.Holder must be sufficiently secure to prevent deflectionfrom the weight of the Gauge.Holder must be rigid enough to hold Gauge and not tolift from measurement force.Holder support arm should be as short as possible toprevent deflection.Deflection or lifting will cause measurement error, suchas origin position error and inaccuracies in measuredreading.Dial Gauge must only be attached by Dovetail or Stem.Mounting of gauge by other than Stem or Dovetail will causeinaccuracy and product damage.Slightly LoosenAttach Mounting Stem.Loosen the Stem mounting bracket and slide thegroove onto the Dovetail in the desired position.Tighten the Stem to secure. (Choose a stem withdiameter to match the Gauge Holder you plan touse.)Confirm that the Probe and stem are securewithout any play.If they are loose, tighten to secure.Attach the Indicator Gauge to the Holder.Please attach by the Stem only.Confirm that the pointer moves freely.Bring the Probe into contact with the workpiece, andgently raise and lower the gauge while checking themovement. Confirm that the pointer returns to initialposition when raised.Make sure the Probe is parallel to themeasured surface, and perpendicular to thedirection of the measurementIf probe is not positioned properly, the measurementwill be inaccurate and operation may be faulty.Set Up Reference Part.Position the reference Part with the measuredsurface parallel to the probe and perpendicular to thedirection of the measurement. Bring into contact withthe probe, but use care that the part does not bumpthe probe from the side.Set the Origin.Adjust the gauge mount or rotate the Bezel to set theGauge to 0.Remove the Reference Part and Measure theWorkpiece.Remove the master with care not to shock the gauge.Replace with the workpiece and read the scale.Position the probe on the workpiece.Position the Part with the measured surface parallel to the probe and perpendicular to the direction of themeasurement. Bring into contact with the probe, but use care that the part does not bump the probe from the side.Set the Origin.Adjust the gauge mount or rotate the Bezel to set the Gauge to 0.Move the workpiece and read the scale.Move the workpiece slowly while reading the position of the pointer on the scale.HOW TO USE - Parallelism, Flatness, Runout, etc.HOW TO USE - Comparison MeasurementsTROUBLESHOOTINGOrigin position shifts during measurement.Temperature changes during measurement can cause repeatability error. Please try the following solutions:Use in location with constant temperature.When taking measurements, periodically adjust zero point using a Master reference to correct for temperatureinduced drift.Make sure the Stem is not loose, and tighten if necessary.Measurement is not stable, or measurement accuracy is poor.Probe may be worn; a worn Probe will affect accuracy. Periodically check for wear, and replace if wear is affectingmeasurement accuracy.DovetailgrooveHOW TO USE - PreparationSPECIFICATIONSRemove any dust or dirt after use. Do not lubricate.Wipe any contamination from Probe and moving surfaces usinga dry cloth, or cloth moistened with alcohol.To clean other surfaces, wipe with a soft dry cloth, or a clothmoistened with a mild cleaner.Check for wear of Probe tip.Measurement accuracy will be affected by worn Probe.Regularly check for wear and replace Probe if worn.Store in provided case in a cool, dark, and dry location.During storage, make sure there is no force on the Probe (suchas pushed in, or lateral force.)Keep away from moisture and direct sunlight, and secure fromunauthorized personnel.Use only factory approved Probe. Using alternate probemay cause error.Always perform calibration after replacing Probe.AFTER USE CARE, STORAGECALIBRATIONTo maintain measurement accuracy, periodic calibration isrecommended.(For reference, we recommend a calibration interval of 3~4 monthswhen used in a factory.)Outside Japan, Please contact distributor or place of purchase toinquire about calibrations services.Niigata seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jp |
Related manuals for Niigata seiki WTI Series
Niigata seiki DT Series User Manual
Niigata seiki DT Series User Manual
Niigata seiki GHS Series User Manual
Niigata seiki GDCS Series User Manual
Niigata seiki D HL Series User Manual
Niigata seiki GDCS Series User Manual
Niigata seiki D-HL Series User Manual
Niigata seiki D Series Manual
Niigata seiki GVC KDE Series User Manual
Niigata seiki WR-100 User Manual
manualsdatabase
Your AI-powered manual search engine