Nikken PIMAG WATERFALL Operating Manual
Also see for PIMAG WATERFALL: Operating manualManual
Contents |
REFILLING THE TANKDo not overfill the unit. If the lower (supply) tank is 1/2 full, do not fill the upper (fill) water tank morethan halfway. Overfilling the tank may cause the unit to overflow.IMPORTANT: The white polymer connector for the wire to the tap assembly is designed to fit in onedirection only. If this is disconnected and resistance is felt when reattaching, do not attempt to force itinto place. Reverse its position to reconnect.MAINTENANCEKeep the PiMag ® Waterfall® Gravity Water System away from direct sunlight.Hand wash the water tanks periodically (approximately once a month) to keep them clean and free ofdeposits. You may use a mild detergent or soap. When cleaning the unit, do not use a scrubber orpaper towels, which may result in scratches on the surface. Use a soft cloth to dry.The prefilter may be rinsed or flushed if it becomes discolored or water flow is reduced. Use cold water only.Do not boil the filter cartridge. Clean only by rinsing in cold water.Component replacementThe replacement filter must be prepared by soaking (preferably for 8 hours) before installation.Follow steps 3 through 5 as described in the Assembly Instructions in this manual.After changing the filter (and prefilter pads), reassemble the Waterfall. Fill the unit with cold water. Thenpress and hold the LED indicator button for 8 to 10 seconds, to reset the indicator for a new cycle. Thedisplay will flash in all colors and then reset to show a green light.• After the water has filled the supply (lower) tank, pull outward on the water tap lever to lift until itlocks in the open position, to drain the Waterfall. Fill and drain the unit while the tap is open, fortwo full cycles.Filter cartridge life will vary, depending on amount of use and water quality.Recommended replacement for mineral stones at least once per year.Replacement partsThe following replacement parts may be ordered from Nikken Inc.Filter cartridge #13845Mineral stones #13846TROUBLESHOOTINGProblem: Unit is leaking.Cause: Loose seal at the water tap.Solution: Make sure that the magnetic tube (inside the water supply tank) is firmly tightened.Do not overtighten.Problem: Water has a disagreeable taste or odor.Cause: Poor water quality or filters need replacing.Solutions: (1) Check quality of water used in system. (2) Clean or replace prefilter. (3) Replace filtercartridge.Problem: Reduced water flow through unit.Cause: Air retained in prefilters.Solution: Remove all five (5) prefilter elements, compress them by squeezing each one under water toexpel air bubbles, replace.7 |
Related manuals for Nikken PIMAG WATERFALL
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine