VBA31001-R.3825.A- A87 ・ D5100 -Measurement.of.consumption.current.valueRefer to "Measurement of consumption current value" of ADJUSTMENT Separate Volume ①.for.details.Standard:Main SW/OFF (NOT any button pressed) 200μA or lessMain SW/ON (Half-release timer: OFF) 190μA or lessMain SW/ON (Half-release timer: ON) 270mA or lessMain.SW/ON.(TFT.monitor:.Light.up). . 290mA.or.lessDuring.LV.(Live.View). . . . 620mA.or.lessDuring.recording.movies. . . . 750mA.or.less•Tool (Device)Use Nikon product.Power.supply(10V 5A)Digital.meter Converted.power.connectorEP-5AInspection and adjustment of "∞ (infinity)" focusRefer to "Inspection and adjustment of "∞ (infinity)" focus" of ADJUSTMENT Separate Volume ①.for.details.Standard:.Range.fm.-0.06.to.+0.06mm-0.06.or.smaller:.Increase.the.washers.(to.increase.thickness)+0.06.or.larger:.Decrease.the.washers.(to.reduce.thickness)•Tool (Device)J19001 J18010 J15441∞ focus collimator F = 600mm Infinity standard lens 50/1.8 Infinity focus adjustment screen297A 1K603-712 washer.T=0.10297B 1K603-713 washer.T=0.20User ID:NHK