51) Option depending on modelATTIX 3 / 5 / 7 / 12 GALLON / 19 GALLON4 Operation4.1.2 Electrical connection The operating voltage shown on therating plate must correspond to thevoltage of the mains power supply.4.1.3 Connecting electricalappliances1)Before switching theswitch to position „auto“,ensure that the tool con-nected to the appliance socket isswitched off.To comply with regulations, only ap-proved dust producing tools shouldbe connected.The maximum power consumptionof the connected electrical appli-ance is stated in section 9.4 "Tech-nical data".4.1 Connections4.1.1 Connecting the suctionhose4.2 Switching on thevacuum cleaner4.2.1 Switch position "I"1. Turn the switch to position"I".The vacuum cleaner motorstarts.1. Connect the suction hose.1. Ensure that the cleaner isswitched off.2. Insert the power cord into aproperly installed and fusedsocket with earthing contact.1. Connect the electrical ap-pliance to the appliancesocket 1) on the control panel.4.2.2 Switch position "auto"1)Before switching theswitch to position „auto“,ensure that the tool con-nected to the appliance socket isswitched off.1. Turn the switch to position"auto" 1) .The vacuum cleaner motorstarts when the connectedpower tool/pneumatic tool isswitched on.2. When the power tool isswitched off, the vacuumcleaner continues to run fora short moment so that anydust in the suction hose isconveyed to the filter bag.4.1.4 Connecting pneumatictools1)Before switching theswitch to position „auto“,ensure that the tool con-nected to the appliance socket isswitched off.Operating pressure of the pneumat-ic tool is stated in section 9.4 "Tech-nical data".1. Connect the pneumatic toolto the upper quick coupling 1)on the control panel.2. Connect the compressed airsupply to the lower push-innipple 1) .