Contents - Table Of Contents
- Table Of Contents
- Safety
- maintenance schedule
- Solution Valve Replacement - 260
- Solution Valve Replacement - 32, 38, 320, 380
- Solution Cable Replacement - 260
- Solution Cable Replacement - 32, 38, 320, 380
- Brush Drive Belt Adjustment - 260
- Brush Drive Belt Adjustment - 32, 38, 320, 380
- Brush Drive Motor - Carbon Brush Inspection - 260
- Brush Drive Motor - Carbon Brush inspection - 32, 38, 320, 380
- Brush Drive Motor Replacement - 260
- Brush Drive Motor Replacement - 32, 38, 320, 380
- Pressure Arm Bearing Replacement - 260
- Pressure Arm Bearing Replacement - 32, 38, 320, 380
- Propelling Linkage Adjustment - 260
- Propelling Linkage Adjustment - 32, 38, 320, 380
- Vacuum Motor - Carbon Brush Inspection - 260
- Vacuum Motor - Carbon Brush Inspection - 32, 38, 320, 380
- Vacuum Motor Removal - 260
- Vacuum Motor Removal - 32, 38, 320, 380
- Squeegee Adjustment - Straight
- Squeegee Adjustment - Curved
- Squeegee Blade Replacement - Straight
- Squeegee Blade Replacement - Curved
- Drive Belt Removal - 32BD, 38BD, 320BHD, 380BHD
- Drive Wheel Removal - 32BD, 38BD, 320BHD, 380BHD
- Main Wheel Removal - 32B
- Differential Removal - 32BD, 38BD, 320BHD, 380BHD
- Caster Replacement
- Batteries
|
56043021 - 260, 32, 38, 320, 380SOLUTION SYSTEM6 Remove the solution cable from the chassis mount (take note of its location in the mount).7 Tip the solution and recovery tanks to the sides of the machine.8 Remove the access panel from the front side of the control panel.9 Disconnect solution cable “M” from solution lever “N”.10 Remove the solution cable from the chassis mount (take note of its location in the mount).11 Work the solution cable up and out of the machine.12 Reassemble in reverse order and test for proper operation.________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________TROUBLESHOOTING________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Problem: Not Enough Solution Flow To The Scrub Brushes1 Kinked solution hoses.2 Solution valve cable needs adjustment.3 Plugged screen in the solution tank (32, 38, 320, 380).4 Plugged solution filter (260 / see figure 1).________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Problem: Solution Leaks With The Valve In The Off Position1 Solution valve cable needs adjustment.2 Solution valve defective.________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Problem: More Solution Flow To One Brush Than The Other1 Kinked solution hoses.________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________SOLUTION CABLE REPLACEMENT - 32, 38, 320, 380 (continued...)13 PreviousNext |