A-18 / ENGLISHA-18 - FORM NO. - 56041619 - Warrior ™ ST, Warrior ™ AXP / BA 755 seriesAFTER USE1 Raise the brushes (or pads) and raise the squeegee. Move the machine to a service area.2 Turn the Master Key Switch (A) OFF and remove the key.3 To empty the solution tank, pull the Solution Drain Hose (16) off the elbow. Direct the hose to a floor drain or bucket. Rinse the tank with clean water.Inspect the solution hoses; replace if kinked or damaged.4 To empty the recovery tank, remove the Recovery Tank Drain Hose (27) from its hanger and remove the cap (hold the end of the hose above the water levelin the tank to avoid sudden, uncontrolled flow of waste water). The Recovery Tank Drain Hose (27) can be squeezed to regulate the flow. Rinse the tank andrecovery tank switch(es) (32) with clean water. Inspect the recovery and vacuum hoses; replace if kinked or damaged. SERVICE NOTE: Make sure you donot get any water down the Vacuum Motor Inlet Screen (4) while cleaning.NOTE: If you have the extended scrub option installed the system will need to be purged.4a After each use, drain and rinse the recovery tank thoroughly and then fill the recovery tank about 1/3 full with clean water.4b Push and hold the Extended Scrub Button (G) for 3 seconds ( the indicator will turn green) to initiate the purge function. The purge will run for 20 seconds.NOTE: This is to flush any debris from the system. If you do not do this, the extended pump and(or) solenoid valve could become plugged up with debris.5 Remove the brushes or pad holders. Rinse the brushes or pads with warm water and hang up to dry. Allow buffing pads to dry completely before usingagain. NOTE: You can either remove the brushes manually or automatically by pressing and holding the Scrub OFF Switch (H) for 5 seconds (AXP/EDSdisk models only).6 Remove the squeegee, rinse it with warm water and hang it up to dry.7 Check the maintenance schedule below and perform any required maintenance before storage.MAINTENANCE SCHEDULE MAINTENANCE ITEM Daily Weekly Monthly YearlyCharge Batteries XCheck/Clean Tanks & Hoses (clean recovery tank switches & vacuum inlet screen) XCheck/Clean/Rotate the Brushes/Pads XCheck/Clean the Squeegee XClean Hopper on Cylindrical System XPurge the Extended Scrub System(if installed) XCheck Each Battery Cell(s) Water Level (does not apply to gel cell batteries) XInspect Scrub Housing Skirts XInspect and clean Solution Filter XClean Solution Manifolds on Cylindrical System XPurge Detergent System (AXP/EDS only) XLubricate the Machine X* Check Carbon Brushes X* Have Nilfisk-Advance check the vacuum motor carbon motor brushes once a year or after 300 operating hours. The brush and drive motor carbon brushescheck every 500 hours or once a year.NOTE: Refer to the Service Manual for more detail on maintenance and service repairs.8 Store the machine in a clean, dry place.9 Turn the Master Key Switch (A) OFF (O) and remove the key.SERVICING THE VACUUM MOTORHave your Nilfisk-Advance Dealer check the carbon motorbrushes once a year or after 300 operating hours.IMPORTANT!Motor damage resulting from failure to servicethe carbon brushes is not covered underwarranty. See the Limited Warranty Statement.LUBRICATING THE MACHINEOnce a month, apply light machine oil to lubricate the:• General Pivot Points For the Squeegee Linkage (A).• Squeegee mount angle adjustment knob threads (B).• Squeegee Tool end wheels (C).• General Pivot Points For the Brush Linkage (D).• Scrub deck bumper wheels.Once per quarter, Grease the following• Rear Caster Wheel Swivels (E).revised 3/06