RH-128Service Tools3. Connection with PC1) RF calibrationRF Cable provides a connection from RF connector on the jig to RF connector on CMU200 orAgilent8960 and executes RF calibration function in AMS.2) SW update / flashingUSB Cable CA-101 provides a connection from the USB port of the personal computer or notebook tothe micro USB connector on Module jig for SW update/flashing.3) Full Phone functionalityPress #0000# , select CIT test >Manual test to perform the phone functionality check. Power on sequence1. S102 @ VCC1 (Power Supply 1 :AC adapter or power service cableVcc1:6.5V-7.5V,Imax=1A); S102 @ VCC2(Power Supply 2)2. S1@ on(power on )3. S101@ On(main current ); S101@ Off (adding a current meter between two red bananaconnectors U52 for current measurement)4. S2 @off (test mode)COMPANY CONFIDENTIALCopyright © 2009 Nokia. All rights reserved.Issue 1Page 3-10