136 Electrical Installation1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where itwill be clearly visible and within easy reach of the operator. In the Hagie cab, a good spotto mount the UC4.5 control panel is on the right hand side of the cab, next to the spraycontroller. If mounting the panel to a round pole, use the rail mount adapter kit (B06)(Figure 12).Figure 12: Mounting the Control Panel Using the Adapter Kit (B06)2. Connect the roll sensor to the 8-way coupler.3. Connect the main lift sensor to the 8-way coupler using cable C04 and a 2-way coupler(E12). Cable C04 and item E12 may not be needed if the 8-way coupler is mounted closeenough to the main lift sensor.4. Connect the sensor on the linear roll cylinder to the 8-way coupler using cable C07 and a2-way coupler (E12).5. Attach a 3-way coupler (E10) to the boom at the inner sensor brackets. Connect twocables (C05) to the 8-way coupler and route along the booms to the inner wing sensors.Plug the sensor and the CANbus cable into the 3-way coupler.6. Connect cable C05 to the remaining connector on the 3-way coupler and route along theboom to the outer wing sensors.7. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.The 2-way coupler with terminator is the white two way coupler. Plug the sensor and theCANbus cable into the 2-way coupler.IMPORTANT:Provide enough slack in all cables to account for the movement of the mainsection, parallel lift, and FOLDING boom movement.