21Figure 26 – Dual Acting Valve BlockAssembly4.5.1.2 Single Acting Assembly1. Install the orifices (F08) into the “B” portswith the notch facing outward as shown inFigure 27.2. Install the 6MB-6MJ fittings (F07) into the“B” ports and tighten to 18 ft-lbs.3. Install the 6MBP plugs (F09) into the “A”ports and tighten to 18 ft-lbs.Figure 27 – Single Acting Valve BlockAssembly4.5.2 Valve Mounting1. Mount the NORAC valve (V01) on thesprayer using the valve mounting bracket(B10).2. Thread a nut onto the short threads of each ofthe threaded studs.3. As shown in Figure 28, screw the short sideof the threaded rods into the bottom of thevalve block and tighten the hex nuts tight tothe valve block.4. Place the valve block onto a frame member,with the studs extending to the other side ofthe member.5. Slide the flat bar from the bracket over thestuds and install a spring washer and nut ontoeach of the studs to hold the plate in place.6. Tighten the two nuts so the valve block isheld on tight and cannot move.7. Cut excess off of the rods, if necessary.If you wish to use bolts, the boltsshould thread into the valve block atleast 3/8". The valve mounting holesare drilled and tapped 3/8 NC-1" deep.The rule of thumb for bolt length is 1-1/2" longer than the tube size.You must ensure no hydrauliccomponents will interfere with anysprayer parts or be pulled tight at anytime.