YESNo Spark at BurnerIs 12 VDC atinput of 1amp fuse?NOYESIs 12 VDCat output of1 amp fuse?NOReplace 1 ampfuse and startrefrigerator.Correct DCsource to 1amp fuse.Is selectorswitch setto Gas?NOYESSet selectorswitch to Gasand startrefrigerator.Is 12 VDC atinput of 20AMP fuse?NOYESCorrect DCsource to 20amp fuse.Is 12 VDCpresent atterminal block?NOYESCorrect DCsource andstart refrigerator.Is circuit breakertripped or fuseblown? (DCto refrigerator)YESNOReset breakeror replace fuseand startrefrigerator.Is thermostatset to start?NOYESSet thermostatto start andlight refrigerator.Is 12 VDC atoutput ofselector switch?NOYESEstablish DCsupply torelighter.Replaceselector switchand startrefrigerator.Remove sparkelectrode wirefrom relighter.YES Is 12 VDC atT1(+) & T3(-)of relighter?NOYESCheck electrodecontinuity -must read ∞.NOReplaceelectrodeassemblyIs relightersparking?NOYES Is electrodepositioned 1/8"max. aboveburner?NOYESReplacerelighter.Adjust electrodeto 1/16" min. -1/8" max.above burner.SpecificationsGas Pressure: 10.5" W.C. - 11" W.C. DC Voltage: 10.5 - 15.4 VDCInstall shortjumper wire fromrelighter to within1/8" of groundNote: If the negative DC supply connection is lost, the flame indicator light will remain on all the time, even withoutthe flame present.Is 12 VDCat input ofselector switch?NOCorrect DCto switchand startrefrigerator.14Manual Compliments ofNorthwest RV SupplyPrinted Fromhttp://www.nwrvsupply.com