Norcold Limited Warranty Time Allowance ChartRialtaTo gain access to the operating controls of the refrig-erator, remove the drawer directly above the refrigera-tor. The interrupter can be replaced without removingthe refrigerator.EuroVanTo gain access to the operating controls of the refrig-erator, remove the control panel assembly locateddirectly above the refrigerator.Heater WiresTo gain access to the AC and DC heater wires,remove the system cover located on the front left sideof the refrigerator.Time AllowanceNorcold will pay the time allowance multiplied by theservice facility prevailing shop labor rate.Note: The time allowances which follow includediagnostic times, defective part replace-ment, refrigerator removal and reinstallation(when applicable), and gas leak test times.A gas leak test is required when gas connections,either the main supply line to the refrigerator or therefrigerator gas components, have been disconnected.Note: In the event of a cooling unit failure, thecomplete refrigerator will be replaced. Thetime allotted to remove and replace thedefective refrigerator will be 1 hr..Replacement PartEuroVanTimeAllowance(Hours)RialtaTimeAllowance(Hours)Burner 1.5 1.5Burner Tube 1.4 1.4Electrode Assembly 1.4 1.4Heater - AC 1.3 1.3Heater - DC 1.3 1.3Flame Indicator Lamp .3 .3Interrupter 1.3 .5Mode Selector Switch 1.3 1.3Orifice 1.3 1.3Relighter .4 .4Safety Valve 1.5 1.5Thermocouple 1.5 1.5Thermostat 1.6 1.6Thermostat By-PassScrew .3 .37