Screen No.8 - 3-Way Models Only DC Heater CurrentThis screen displays the measured DC heater current (decimal point is implied).A. Identifies information screen.B. The control displays the current through the DC heater measured by the control over a range of 9 to 21 amperes. (Figure 12indicates 16 amps).C. Indicates BATT (DC heater) mode of operation.To verify:Measure DC current through the DC heater. The current will be +/- 10% of the control’s display.Internal Control Information-9100 SeriesScreen No. 1 - Input and OutputA - Identifies information screen.1 - Not Applicable2 - Not Applicable3 - All modes of operation. LED on signifies the freshfood compartment door is closed and the interior lightis off.4 - LP GAS mode, LED on signifies a burner flamepresent at the burner.5 - AC electric mode, LED on signifies that the powerboard is supplying AC voltage to power the AC heater.6 - BATTERY mode, LED on signifies the powerboard is supplying DC voltage to power the DC heater.7 - All modes of operation, LED on signifies thepower board is supplying DC voltage to power themoisture reduction (divider) heater.8 - LP GAS mode, LED on signifies the power boardis supplying power to the gas valve.9 - All modes of operation, LED on signifies thepower board is supplying DC voltage to activate theinterior light.Screen No. 2ABCFigure 1224