Contents - Table Of Contents
- SPECIFICATIONS
- EXPLODED VIEW
- DIAGNOSTICS
- Reading the LED
- DIAGNOSTIC SYMPTOM CHART
- TROUBLESHOOTING
- Troubleshooting - Test B, Fan Cut-Out
- Troubleshooting - Test C, Motor Start Error
- Troubleshooting - Test D, Minimum Motor Speed Error
- Troubleshooting - Test E, Electronic Unit Thermal Cut-Out
- Troubleshooting - Test F, Not Cooling, Not Turning On
- Troubleshooting - Test G, Refrigerator Gets Too Cold
- Troubleshooting - Test H, Refrigerator Builds Frost Inside
- Troubleshooting - Test I, Runs but Does Not Cool
- Troubleshooting - Test J, Will Not Run On DC Power
- TEST UNIT
|
18 Refrigerator Service Manual / Manuel d'entretien du réfrigérateur / Manual de servicio del refrigeradorModelos N1090/ Modèles N1090/ Modelos N1090Troubleshooting, cont’d.Possible Cause:■ Blown fuse in DC circuit■ Undersized wiring to refrigerator,minimum #12 gauge wire required,refer to Installation Manual for rec-ommended wire size■ Partially discharged battery, volt-age below 11.3 VDC at compressormodule■ High resistance (voltage drop) insupply circuitTroubleshooting - Test J, Will Not Run On DC PowerIs wiring to refrigerator at least 12 AWG(required)?STARTReplace fuse; test unit.Is voltage below 11.3 VDC atcompressor module?Perform Diagnostic Prechecks.Is the DC fuse intact? NoYesYesZĞĨĞƌƚŽ/ŶƐƚĂůůĂƟŽŶDĂŶƵĂůĨŽƌrecommended wire size.NoZĞĐŚĂƌŐĞŽƌƌĞƉůĂĐĞďĂƩĞƌLJ͖test unit.YesNoCorrect high resistance;ǀŽůƚĂŐĞĚƌŽƉͿŝŶƐƵƉƉůLJĐŝƌĐƵŝƚ͘NOR000726j-10a