Installation Manual 12Ignition - propane gas operation:Press the ON / OFF button [30] to start the refrigerator in automode.- Push and hold the MODE button [31] until the light bar flashesin the center display [33] beside LP GAS [36].- Release the MODE button.On initial start up of the refrigerator, ignition of thepropane gas may not occur within 30 seconds.If ignition of the propane gas does not occur within 30 seconds:- The gas safety valve of the refrigerator closes.- The refrigerator stops operation.- Refer to the “Fault Codes“ section of this manual.- The fault code remains until you push the ON / OFF button two times (to stop and start the refrigerator).- If ignition does not occur after two or three times:- Check the gas supply line.- Consult your local dealer or an authorized Norcold Service Center.- Change to manual mode and operate on AC electric.Ignition Start Up- To prevent vibration and abrasion, make sure that the gas supply line is not against anything in the enclosure.- Attach the gas supply line to the bulkhead fiting [91] of the refrigerator (See Art00975).Examine the gas supply system for leaks:Do not allow the leak detecting solution to touch the electrical components. Many liquids are electricallyconductive and can cause a shock hazard, electrical shorts, and in some cases, fire.Use a leak detecting solution to examine the gas supply line and all propane gas connections for leaks.If you use compressed air for the test:- The pressure at the manual shut off valve of the refrigerator must not be more than 1/2 psig (14 inches Water Column).- If the air pressure is more than 1/2 psig (14 inches Water Column), remove the gas supply line from the bulkhead fitting of therefrigerator before the test.- If the air pressure is equal to or less than 1/2 psig (14 inches Water Column), close the manual shutoff valve of the refrigeratorbefore the test.WARNING!NOTICE