Description2-6Part 1615897-01 2019 Nordson CorporationSpecificationsGeneralSee Figures 2-6 for controller dimensions.Electrical RequirementsInput(See Note B)100−250 Vac, 50−60 Hz, 1 Phase, 400VA max.Conveyor Interlock, Remote Lockout: 120/230 Vac, 50/60 Hz, 1 ∅, 6 mAOutput (to spray gun) ± 19V, ±1A (peak)CAN 1 (manual gunconnection)24 V, ±10% at 4A FusedNOTE A: The controller must be interlocked with the fire detection system so that the spray guns are shutoff if a fire is detected inside the spray booth.NOTE B: Branch circuit breaker 10A MaximumD I/OLockout(Open=System Lockout)24 V 5 mA, Contact ClosureAlarm(Contacts Closed=SystemGoodContact Closure 60 V maximum at 1AANSI/ISA S82.02.01Pollution Degree 2Installation (Overvoltage) Category IIEnvironmentalOperating Temperature +15 C to +40 COperating Humidity 5−95%, non-condensingWeight16 Spray Gun Controller 137 kg (302 lb)Note B: Branch circuit breaker 10A Max.Input Air Quality RequirementAir must be clean and dry. Use a regenerative desiccant or refrigerated airdryer capable of producing a 3.4 oC (38 oF) or lower dew point at 7 bar(100 psi) and a filter system with prefilters and coalescent-type filterscapable of removing oil, water, and dirt in the submicron range.Recommended Air Filter Screen Size: 5 micron or smallerMaximum Oil Vapor in Air Supply: 0.1 ppmMaximum Water Vapor in Air Supply: 0.48 grains/ft3Moist or contaminated air can cause the HDLV pumps to malfunction; thepowder to cake in the reclaim system, or cause clogging in the feed tubingor spray gun powder paths.