15100 105 110 115 120An alarm will sound for tenseconds when the flowreaches the set level.The water will continue to run unless it ismanually turned off. * Initial factory setting: 110°FWater TemperatureThe temperatures settings below are only examples. Thetemperature setting necessary will depend on the usage,the length of piping and the time of year.(°F: )Warmer HotWarm5 Turn off the hotwater when thealarm sounds.4 Turn on hotwater.3 Adjust flow meteralarm setting.To set the flow meter alarm:Press the flow meter alarm set button(the setting will flash on the display)and adjust with the setting buttons.IncreaseDecreaseChoose the flow meter alarm settingfrom the following options: 10 - 60(In 5 gallon intervals), 70 - 100 (In10 gallon intervals), or 990 gallons.Note: The alarm will not sound ifit is set for 990 gal.Note: The alarm will notsound if it is set for990 gal.OnFlow meter setting will be flashing(ex. 45 gal.)* The level can only be adjustedwhile the indicator is flashing.* After ten seconds, the remotewill again display the temperature.OffIf the flow meter alarm is being used to indicate when a tub is full:• If any hot water is being used besides what is going into the tub, the alarm will sound beforethe tub is full.• If there was water in the tub before the fill began, or if the water is not shut off manually whenthe alarm sounds, the tub may overflow.• If there was water in the tub before the fill began, the temperature in the tub after it is full maybe different from the temperature setting.The alarm will sound whenthe set level has beenreached. Stop the water.