18* Damage can occur from frozen water within the device and pipes even in warm environments.Be sure to read below for appropriate measures.* Repairs for damage caused by freezing are not covered by the warranty.Freezing cannot be prevented when the power plug is unplugged. Do not remove the powerplug from the wall outlet.(Freezing will be prevented regardless of whether the operation switch is ON or OFF.)* Remember to set mixing valves and fixtures to their original levels before using the unit againto prevent scalding.* If there is still a risk that the unit will freeze, drain the unit as shown on the next page.0.2" thickHot Water FixturePreventing Damage from Freezing-1Freezing is prevented within the device automatically by the freeze-prevention heaterCAUTIONTake the measures below for extremely cold temperatures*.(outside temperature including wind chill factor less than -30°F (indoor installation) or-4°F (outdoor installation)).This method can protect not only the heater, but also the water supply,water piping and mixing valves.1. Turn the unit on with the Power Button on the Remote Controller.2. Close the gas supply valve.3. Open a hot water fixture and let it run for approx. 2 minutes, and thencheck that the number 11 is flashing on the remote controller display.* If multiple units are being used, drain two minutes for each unit.* It is possible that a different number may be displayed on theremote controller, but as long as it is flashing, you may continue.4. Partially close the hot water fixture, but keep a small amount of hot water running(0.1 gal./minute or about 0.2” thick).* If there is a mixing valve, set it to the highest level.* When linking multiple units, discharge water equivalent to 0.1 gal./minute per unit.5. The flow may become unstable from time to time. Check the flow 30 minutes later.If water will not flow because it is frozen1. Close the gas and water valves.2. Turn off the power button.3. Open the water supply valve from time to time to check whether water is running.4. When the water is flowing again, check for water leaks from the equipment and piping before using.If the heater or the piping is frozen, do not use the heater or it may get damaged.* In normal operation, freezing is prevented within the device automatically unless the outsidetemperature without wind is below -30°F (indoor installation) or -4°F (outdoor installation).* The freeze prevention heaters will not prevent the plumbing external to the unit from freezing.Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers.If there remains a freezing risk, contact the nearest Noritz agent.