Page 214 of 284 Installing a Signaling ServerNN43021-469 Standard 01.01 May 2007Installing the softwareTo install software and enter basic system configuration parameters on anIBM X306m or HP DL320-G4 Signaling Server, complete Procedure 60.Procedure 60Installing Signaling Server softwareUpon completion of Step 1, this procedure takes approximately 45 minutes tocomplete.1 From your Planning and Engineering group, obtain the following networkand IP Telephony data for this Signaling Server:• node ID for the IP Telephony node• node IP address for the IP Telephony node• hostname for the Signaling Server• ELAN network interface IP address, Subnet mask, and Gateway• TLAN network interface IP address, Subnet mask, and Gateway• ELAN network interface IP address of the Call Server• Primary and Alternate NRS IP addresses for this networked system.Refer toIP Peer Networking: Installation and Commissioning(NN43001-313)• NRS role, if applicable. Refer to IP Peer Networking: Installation andCommissioning (NN43001-313)2 Boot the Signaling Server from the Removable Media Device (RMD):• For IBM X306m, HP DL320-G4, or Nortel ISP1100 SignalingServers, insert the CS 1000 Release 5.0 Signaling Server SoftwareCD into the CD drive and press the RST button on the front panel ofthe Signaling Server to trigger a cold boot. This forces the SignalingServer to boot from the CD.• For a Nortel CP PM Signaling Server, insert the CS 1000 Release 5.0Signaling Server Software CF card into the faceplate CF drive andpress the RST button on the faceplate of the Signaling Server totrigger a cold boot. The CP PM System BIOS Configuration screenappears (see Figure 52) with an instruction to press F to force theSignaling Server to boot from the CF card.