Page 8 of 8 — DN-7070:H • 12/19/2011System Capacity• Intelligent Signaling Line Circuits ...........1 expandable to 10• Intelligent detectors .......................................... 159 per loop• Addressable monitor/control modules .............. 159 per loop• Programmable software zones ............................. over 2000• ACS annunciatorsper CPU2-3030 .......................32 address x 64 or 96 pointsNOTE: The CPU2-3030 can support up to 96 annunciatoraddress points per ACM-24/-48.Specifications• Primary input power:– AMPS-24: 110-120 VAC, 50/60 Hz, 4.5 A maximum.– AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum.• DC output:– Main 24 VDC: Up to 5.0 A– Aux 24 VDC: Up to 5.0 A– 5 VDC: Up to 0.15 A.NOTE: For details of DC output values, see manual 51907.• Battery charger range: 7 AH – 200 AH. Use separate cab-inet for batteries over 26 AH.• Float Rate: 27.6 V.Shipping Weight– CPU2-3030D: 5.95 lb (2.70 kg).– CPU2-3030ND: 2.90 lb (1.32 kg).Temperature and Humidity RangesThis system meets NFPA requirements for operation at 0 –49°C/32 – 120°F and at a relative humidity 93% ± 2% RH(noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, theuseful life of the system's standby batteries and the electroniccomponents may be adversely affected by extreme tempera-ture ranges and humidity. Therefore, it is recommended thatthis system and its peripherals be installed in an environmentwith a normal room temperature of 15 – 27°C/60 – 80°F.Agency Listings and ApprovalsThese listings and approvals apply to the modules specified inthis document. In some cases, certain modules or applicationsmay not be listed by certain approval agencies, or listing maybe in process. Consult factory for latest listing status.• UL Listed: S635.• ULC Listed: S635.• MEA: 232-06-E.• FDNY: COA#6065.• CSFM: 7165-0028:0224 (Commercial).• FM Approved.• FM6320 Approved. Class 6320 for Gas Detection.• City of Chicago.• City of Denver.• PSB Corporation.• CCCF listed.• Fire Services Department (Hong Kong).StandardsThe NFS2-3030 complies with the following UL Standards andNFPA 72, IBC, and CBC Fire Alarm Systems requirements:• UL 864 (Fire).• UL 1076 (Burglary).• LOCAL (Automatic, Manual, Waterflow and SprinklerSupervisory).• AUXILIARY (Automatic, Manual and Waterflow) (requiresTM-4).• REMOTE STATION (Automatic, Manual, Waterflow andSprinkler Supervisory) (requires TM-4).• PROPRIETARY (Automatic, Manual, Waterflow and Sprin-kler Supervisory). Not applicable for FM.• EMERGENCY VOICE/ALARM.• OT, PSDN (Other Technologies, Packet-switched Data Net-work).• IBC 2000, IBC 2003, IBC 2006, IBC2009 (Seismic).• CBC 2007 (Seismic).IntelliQuad™ and NOTI•FIRE•NET™ are all trademarks; and Acclimate®Plus™, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are allregistered trademarks of Honeywell International Inc.©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited.Made in the U.S. A.This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.comSYSTEM SPECIFICATIONS