72DispType (DisplayType): The options for this setting are the same as for CC however the ‘REL1’, ‘REL2’ and ‘APOT’ displaytypes are not available for encoders.Length: This determines the length of the sysex message sent when the control is operated. The value sets the number ofbytes and is variable between 0 and 12, or 9 and 12 for ROLAND type sysex messages.DataType: This allows you to set the format of the sysex message as follows:NONE: Sysex message does not contain a variable byte and a fixed message is sent every time the control is operated.SINGLE: Sysex message contains one variable byte. The value of this byte is determined by the current control valueand limited by the Low Value and High Value settings. The position of the variable byte in the sysex message canbe edited.ROLAND: Sysex message contains one variable byte and one checksum byte. The value of the variable byte isdetermined by the current control value and limited by the Low Value and High Value settings. The format of the sysexmessage is fixed such that the second-to-last byte is always the variable byte and the last byte is always the checksumbyte (excluding the F7 byte).If an encoder has DispType set to ‘0-16K’ then the options for DataType are as follows:NONE: Sysex message does not contain a variable byte and a fixed message is sent every time the control is operated.LSB-MSB: Sysex message contains two variable bytes which form an MSB and LSB pair, allowing a 14-bit value to betransmitted. The LSB precedes the MSB in the sysex message. The two bytes cannot be separated by non-variablebytes but the position of the pair of bytes in the message can be edited.MSB-LSB: This is the same as LSB-MSB except the MSB precedes the LSB in the sysex string.ROLAND: Sysex message contains two variable bytes and one checksum byte. The format of the message is fixed suchthat the last three bytes of the string are always MSB, then LSB and then checksum (excluding the F7 byte).DataPsn (Data Position): This allows you to set the position of the variable data byte(s) in the sysex message. This valuewill automatically be constrained by the Length setting. Note that if DataType is set to ROLAND then this value will befixed, as the format of ROLAND sysex messages cannot be edited.To edit the value of each of the non-variable bytes in the sysex message scroll up to the sysex message page. All bytesare displayed in hexadecimal format. By default the ReMOTE SL will place an F0h at the start and F7h at the end of themessage and set all other non-variable bytes to 00h. Variable bytes appear as ‘DV’ and a checksum byte will appear as ‘CS’- these cannot be edited.To edit a byte use the buttons or encoders in line with the ‘<<’ and ‘>>’ symbols to navigate the cursor to the desired byteand then use the buttons, encoder or pot in line with ‘VALUE’ to set the value (range 00 to 7F). Scroll down after editingthe sysex message to return to the control settings.14.5 MIDI MACHINE CONTROL (MMC)The Ports setting is the same as for Control Change (CC) so see that section for information on these settings.