Event Source Management 225novdocx (en) 7 January 201010.7.4 Redo LayoutTo redo layout changes:1 Click View on the Menu Bar and select Redo Layout. Alternatively, click the Redo Layoutbutton on the Tool Bar.10.8 Event Source Management ScratchpadScratchpad is the “Design Mode of the Health Monitor”. Through Scratchpad you can design andconfigure: Collector Managers Collectors Event Sources Connectors Event Source ServersYou can right-click the Sentinel icon and add the components. For more information, seeSection 10.4.2, “Adding Components to Event Source Hierarchy,” on page 194.NOTE: You cannot view the status of any object in the design mode as they are not connected to aninstance of a real Collector Manager.10.9 Comparison between Sentinel 5.x andSentinel 6.0The following Sentinel 5 components have been rolled up into ESM. Along with the Sentinel 5component name, there is a hint at where to find the related functionality in ESM.Table 10-7 Comparison TableComponents Sentinel 5.x Sentinel 6.0Build / Edit Collector Building, Modifying or editing aCollector was possible in CollectorBuilder in 5.xBuilding, Modifying or editing aCollector is possible in CollectorBuilder in 6.0Import Collector Importing a Collector is not applicablein 5.xYou can import a Collector fromSentinel Control Center in 6.0Deploy Collector Deploy Collector was possible inCollector Builder in 5.xDeploy Collector is possible in SentinelControl Center in 6.0Debug Collector A debugging interface that enabled auser to step through the parsing logicin a Collector. This interface wasavailable in Collector Builder inSentinel 5.xIn ESM, this is now done through theESM panel in Sentinel Control Center.To debug a Collector in ESM, rightclick the Collector node you want todebug and select the Debug option.