www.novikneo.com4PANEL INSTRUCTIONSFront Panel1. Main Power SwitchWhen press the switch, the soft start circuit run for avoiding surge strike. In about 3-4seconds, there will be a clicking denote that soft start finished. And more 1-2 secondslater, there will be another “clicking”, the amplifier is connected with speaker andready to work.2. Channel A / Channel B Input level controlAdjust it to get the volume desired.3. Channel A / Channel B Protection indicating ledThis led will light up when the amplifier is running un-stable or went in to thermalprotection after the power elements temperature over 90°.4. Clip ledTurns on just before the maximum, distortion free, output level of the amplifier. Theclip leds may turn on shortly from time to time but they may certainly not turn on forlonger periods. In this case you have to turn the output level down.5. Signal ledThe green signal led indicates that a music signal is present at this channel input.6. Bridge mode indicating ledIndicate the amplifier is working under BRIDGE mode, the indicator is lighten, and theinput signal acts on CH.A and CH.B7. Stereo mode indicating ledThese green led will light up while the input signal is connected, the amplifier isworking under stereo mode.12 634 57 2