INSTALLATION INSTRUCTIONSREAD & SAVE THESE INSTRUCTIONS!Heat-A-Ventlite ®CombinationMODEL: 665RPType IC suitable for use under thermal insulationLOCATION1. Mount heater to ceiling joists, or if necessary, to a headerinstalled between joists.2. Caution: Do not mount heater closer than 12" to avertical surface. Do not mount over tub or in showerenclosure.3. Installation in existing construction requires an accessiblearea above the desired location. Make sure that wiringand ducting can be run to the location.MOUNTING HEATER HOUSINGFIGURE 1NEW CONSTRUCTIONUsing Hanger BarsRefer to Figure 1.1. Insert hanger bars in slots provided in housing.2. Locate heater housing between joists so that bottom of heater housing is even with the planned finished ceiling.3. Use screws or nails (not provided) to secure hanger bars to ceiling joists.Using Side Mounting Tabs1. Locate heater housing next to ceiling joist.2. Use wood screws (not provided) through keyhole slots in mounting tabs to loosely attach housing to ceiling joist.3. Adjust housing so that it will be flush with the finished ceiling. When housing is properly adjusted, tighten screw in slots tosecure housing.EXISTING CONSTRUCTION1. Determine desired location for heater.2. Drill a small hole through the ceiling at the desired location and stick a coat hanger or stiff wire through hole into attic tohelp find the location from above.3. Check the area above to make sure that wiring and ducting can be installed and that the installation will not interfere withexisting electrical wiring.4. From above, place the housing between ceiling joists at the desired location. Using the housing as a template, mark thearea to be cut out along the bottom flange of the housing.5. After making the cutout, install the housing in the opening using the hanger bars or mounting tabs as described above.Make sure that the bottom of the housing is flush with the bottom of the finished ceiling.