Page 1MODEL 755DECORATIVE SERIESCEILING VENTILATORREAD AND SAVE THESE INSTRUCTIONSWARNINGTO REDUCE THE RISK OF FIRE, ELECTRICSHOCK, OR INJURY TO PERSONS, OB-SERVE THE FOLLOWING:1. Use this unit only in the manner intended bythe manufacturer. If you have questions, con-tact the manufacturer at the address or tele-phone number listed in the warranty.2. Before servicing or cleaning unit, switch poweroff at service panel and lock the service dis-connecting means to prevent power from be-ing switched on accidentally. When the ser-vice disconnecting means cannot be locked,securely fasten a prominent warning device,such as a tag, to the service panel.3. Installation work and electrical wiring must bedone by a qualified person(s) in accordancewith all applicable codes and standards, in-cluding fire-rated construction codes and stan-dards.4. Sufficient air is needed for proper combus-tion and exhausting of gases through the flue(chimney) of fuel burning equipment to pre-vent backdrafting. Follow the heating equip-ment manufacturer’s guideline and safetystandards such as those published by theNational Fire Protection Association (NFPA),and the American Society for Heating, Refrig-eration and Air Conditioning Engineers(ASHRAE), and the local code authorities.5. When cutting or drilling into wall or ceiling, donot damage electrical wiring and other hid-den utilities.6. Ducted fans must always be vented to the out-doors.7. NEVER place a switch where it can bereached from a tub or shower.8. This unit must be grounded.9. This unit is U.L. listed. Type I.C. inherentlyprotected.CAUTION !1. For general ventilating use only. Do not useto exhaust hazardous or explosive materialsand vapors.2. This product is designed for installation inFLAT CEILINGS ONLY. Do not mount thisproduct in a wall.3. The light fixture assembly must be mountedto the fan housing assembly included with thisproduct. Do not mount the light fixture as-sembly to a wiring outlet box.4. To avoid motor bearing damage and noisyand/or unbalanced impellers, keep drywallspray, construction dust, etc. off power unit.5. Please read specification label on product forfurther information and requirements.TYPICAL INSTALLATIONSHOUSING MOUNTEDTO ADDITIONAL FRAMINGDischarge 90 0 to joists.HOUSING MOUNTEDDIRECTLY TO JOIST2x6 (or larger)Discharge parallel to joists.HOUSING MOUNTEDTO 2x4 TRUSSRequires additional framingfor mounting tabs.Discharge parallel to joists.HOUSING MOUNTED TO “I” JOISTRequires additional framingfor mounting tabs.Discharge parallel to joists.HOUSING MOUNTED TO 2x4TRUSSRequires additional framingfor mounting tabs.Discharge 90 0 to joists.HOUSING MOUNTED TO “I” JOISTRequires additional framingfor mounting tabs.Discharge 90 0 to joists.Installer: Leave this manual with the homeowner.Homeowner: Use and Care information on page 4.* Additional framing must be a 2x6 (minimum height), at least 9-inches long.*****